Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record.

Ultrahigh finesse Fabry-Pérot superconducting resonator

Open access
Kuhr, S., Gleyzes, S., Guerlin, C., Bernu, J., Hoff, U. B., Deléglise, S., Osnaghi, S., Brune, M., Raimond, J.-M., Haroche, S., Jacques, E., Bosland, P., Visentin, B.·2007·Applied Physics Letters

Abstract

The authors have built a microwave Fabry-Pérot resonator made of diamond-machined copper mirrors coated with superconducting niobium. Its damping time (Tc=130ms at 51GHz and 0.8K) corresponds to a finesse of 4.6×109, the highest ever reached for a Fabry-Pérot in any frequency range. This result opens many perspectives for quantum information processing, decoherence and nonlocality studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.2724816

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 238

Metadata

Authors
Kuhr, S., Gleyzes, S., Guerlin, C., Bernu, J., Hoff, U. B., Deléglise, S., Osnaghi, S., Brune, M., Raimond, J.-M., Haroche, S., Jacques, E., Bosland, P., & Visentin, B.
Venue
Applied Physics Letters
Published
2007-04-16
Volume
90
Issue
16
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2034549000
Cited by
238
References
0
FWCI
22.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrahigh finesse Fabry-Pérot superconducting resonator. https://app.cochat.ai/papers/10.1063/1.2724816
The paper
Kuhr, S., Gleyzes, S., Guerlin, C., Bernu, J., Hoff, U. B., Deléglise, S., Osnaghi, S., Brune, M., Raimond, J.-M., Haroche, S., Jacques, E., Bosland, P., & Visentin, B. (2007). Ultrahigh finesse Fabry-Pérot superconducting resonator. Applied Physics Letters. https://doi.org/10.1063/1.2724816

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.