Retrieving the susceptibility from time-resolved terahertz experiments
Open accessAbstract
We present an analytical expression for the observed signal in time- and phase-resolved pump-probe studies, with particular emphasis on terahertz time-domain spectroscopy. Maxwell’s equations are solved for the response of damped, harmonic oscillators to a driving probe field in the perturbative regime. Our analytical expressions agree with the one previously reported in the literature [Nemec et al., J. Chem. Phys. 122, 104503 (2005)] in the Drude limit; however, they differ in the case of a vibrational resonance.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The straightforward interpretation of THz-TDS as a snapshot of the optical conductivity spectrum breaks down when characteristic relaxation times are comparable to the photoexcitation delay, because the Fourier transform involves times that precede photoexcitation.
“However, the straightforward interpretation of THz-TDS as a snapshot of the optical conductivity spectrum breaks down when the characteristic relaxation times are comparable to the photoexcitation delay, because the Fourier transform involves times that precede photoexcitation. 1,9-16”
From Terahertz time-domain spectroscopy of transient metallic and superconducting states (2015) · cites this paper as [14]
The damping term decreases when the carrier density increases, because the model incorrectly assumes that all carriers move with the same velocity.
“Conversely, the damping term decreases when the carrier density increases, because our model incorrectly assumes that all carriers move with the same velocity. 14”
From Terahertz time-domain spectroscopy of transient metallic and superconducting states (2015) · cites this paper as [14]
Similar oscillations in Σ(ω;t_s) were observed previously in measurements and simulations, and Eq. 13 clarifies their origin.
“Similar oscillations were observed previously in both measurements 18 and simulations, 14 and Eq. 13 clarifies their origin.”
From Terahertz time-domain spectroscopy of transient metallic and superconducting states (2015) · cites this paper as [14]
The citation lists haven’t been fetched yet
References 29 · Cited by 8
- Authors
- Schins, J. M., Hendry, E., Bonn, M., & Muller, H. G.
- Affiliations
- Delft University of Technology (NL)
- University of Exeter (GB)
- Institute for Atomic and Molecular Physics (NL)
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 2007-09-07
- Volume
- 127
- Issue
- 9
- Pages
- 094308-094308
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2160112769
- Cited by
- 8
- References
- 29
- Citations by year
- 2024: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2015: 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- green
- resolver.tudelft.nl
- Licence
- other-oa
- Locations
- The Journal of Chemical Physics (publishedVersion)
- PubMed (publishedVersion)
- Figshare (submittedVersion)
- Open Research Exeter (University of Exeter) (submittedVersion)
- Research Repository (Delft University of Technology) (submittedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
- Keywords
- time-resolved terahertz spectroscopy, pump-probe spectroscopy, phase-resolved spectroscopy, damped harmonic oscillator, Drude model, vibrational resonance, Maxwell's equations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review