Cited by 8Terahertz technology and applicationsLaser-Matter Interactions and ApplicationsSpectroscopy and Quantum Chemical Studies

Retrieving the susceptibility from time-resolved terahertz experiments

Open access
Schins, J. M., Hendry, E., Bonn, M., Muller, H. G.·2007·The Journal of Chemical Physics

Abstract

We present an analytical expression for the observed signal in time- and phase-resolved pump-probe studies, with particular emphasis on terahertz time-domain spectroscopy. Maxwell’s equations are solved for the response of damped, harmonic oscillators to a driving probe field in the perturbative regime. Our analytical expressions agree with the one previously reported in the literature [Nemec et al., J. Chem. Phys. 122, 104503 (2005)] in the Drude limit; however, they differ in the case of a vibrational resonance.

Integrity signals

Registry

Crossref · 10.1063/1.2761915

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The straightforward interpretation of THz-TDS as a snapshot of the optical conductivity spectrum breaks down when characteristic relaxation times are comparable to the photoexcitation delay, because the Fourier transform involves times that precede photoexcitation.

    “However, the straightforward interpretation of THz-TDS as a snapshot of the optical conductivity spectrum breaks down when the characteristic relaxation times are comparable to the photoexcitation delay, because the Fourier transform involves times that precede photoexcitation. 1,9-16”
  • The damping term decreases when the carrier density increases, because the model incorrectly assumes that all carriers move with the same velocity.

    “Conversely, the damping term decreases when the carrier density increases, because our model incorrectly assumes that all carriers move with the same velocity. 14”
  • Similar oscillations in Σ(ω;t_s) were observed previously in measurements and simulations, and Eq. 13 clarifies their origin.

    “Similar oscillations were observed previously in both measurements 18 and simulations, 14 and Eq. 13 clarifies their origin.”

The citation lists haven’t been fetched yet

References 29 · Cited by 8

Authors
Schins, J. M., Hendry, E., Bonn, M., & Muller, H. G.
Affiliations
  • Delft University of Technology (NL)
  • University of Exeter (GB)
  • Institute for Atomic and Molecular Physics (NL)
Venue
The Journal of Chemical Physics
Published
2007-09-07
Volume
127
Issue
9
Pages
094308-094308
ISSN
  • 0021-9606 (ISSN-L)
  • 1089-7690
OpenAlex
W2160112769
Cited by
8
References
29
Citations by year
2024: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2015: 1
FWCI
0.63
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • The Journal of Chemical Physics (publishedVersion)
  • PubMed (publishedVersion)
  • Figshare (submittedVersion)
  • Open Research Exeter (University of Exeter) (submittedVersion)
  • Research Repository (Delft University of Technology) (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
Keywords
time-resolved terahertz spectroscopy, pump-probe spectroscopy, phase-resolved spectroscopy, damped harmonic oscillator, Drude model, vibrational resonance, Maxwell's equations

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review