Improved fabrication of zero-mode waveguides for single-molecule detection
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Metallic subwavelength apertures can be used in epi-illumination fluorescence to achieve focal volume confinement. Because of the near field components inherent to small metallic structures, observation volumes are formed that are much smaller than the conventional diffraction limited volume attainable by high numerical aperture far field optics (circa a femtoliter). Observation volumes in the range of 10−4fl have been reported previously. Such apertures can be used for single-molecule detection at relatively high concentrations (up to 20μM) of fluorophores. Here, we present a novel fabrication of metallic subwavelength apertures in the visible range. Using a new electron beam lithography process, uniform arrays of such apertures can be manufactured efficiently in large numbers with diameters in the range of 60–100nm. The apertures were characterized by scanning electron microscopy, optical microscopy, focused ion beam cross sections/transmission electron microscopy, and fluorescence correlation spectroscopy measurements, which confirmed their geometry and optical confinement. Process throughput can be further increased using deep ultraviolet photolithography to replace electron beam lithography. This enables the production of aperture arrays in a high volume manufacturing environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Cited by
Real-Time DNA Sequencing from Single Polymerase Molecules
Eid, J., Fehr, A., Gray, J., Luong, K., Lyle, J., Otto, G., Peluso, P., Rank, D., Baybayan, P., Bettman, B., et al. (2009) · Science · doi:10.1126/science.1162986 · Cited by 3,732
Self-citationDirect detection of DNA methylation during single-molecule, real-time sequencing
Flusberg, B. A., Webster, D. R., Lee, J. H., Travers, K. J., Olivares, E. C., Clark, T. A., Korlach, J., & Turner, S. W. (2010) · Nature Methods · doi:10.1038/nmeth.1459 · Cited by 1,460
“ZMW nanostructures were fabricated and functionalized as previously describe”
MethodIntegrating Artificial Intelligence and Nanotechnology for Precision Cancer Medicine
Adir, O., Poley, M., Chen, G., Froim, S., Krinsky, N., Shklover, J., Shainsky‐Roitman, J., Lammers, T., & Schroeder, A. (2020) · Advanced Materials · doi:10.1002/adma.201901989 · Cited by 496
Landscape of Next-Generation Sequencing Technologies
Niedringhaus, T. P., Milanova, D., Kerby, M. B., Snyder, M. P., & Barron, A. E. (2011) · Analytical Chemistry · doi:10.1021/ac2010857 · Cited by 378
Real-time tRNA transit on single translating ribosomes at codon resolution
Uemura, S., Aitken, C. E., Korlach, J., Flusberg, B. A., Turner, S. W., & Puglisi, J. D. (2010) · Nature · doi:10.1038/nature08925 · Cited by 351
Self-citation
Metadata
- Authors
- Foquet, M., Samiee, K. T., Kong, X., Chauduri, B. P., Lundquist, P. M., Turner, S. W., Freudenthal, J., & Roitman, D. B.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2008-02-01
- Volume
- 103
- Issue
- 3
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2087829969
- Cited by
- 104
- References
- 2
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved fabrication of zero-mode waveguides for single-molecule detection. https://app.cochat.ai/papers/10.1063/1.2831366
- The paper
- Foquet, M., Samiee, K. T., Kong, X., Chauduri, B. P., Lundquist, P. M., Turner, S. W., Freudenthal, J., & Roitman, D. B. (2008). Improved fabrication of zero-mode waveguides for single-molecule detection. Journal of Applied Physics. https://doi.org/10.1063/1.2831366
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.