The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hard-x-ray microscopy with Fresnel zone plates reaches 40nm Rayleigh resolution
Open accessAbstract
Substantial improvements in the nanofabrication and characteristics of gold Fresnel zone plates yielded unprecedented resolution levels in hard-x-ray microscopy. Tests performed on a variety of specimens with 8–10keV photons demonstrated a first-order lateral resolution below 40nm based on the Rayleigh criterion. Combined with the use of a phase contrast technique, this makes it possible to view features in the 30nm range; good-quality images can be obtained at video rate, down to 50ms∕frame. The important repercussions on materials science, nanotechnology, and the life sciences are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Cnudde, V., & Boone, M. N. (2013) · Earth-Science Reviews · doi:10.1016/j.earscirev.2013.04.003 · Cited by 1,572
Ptychographic X-ray computed tomography at the nanoscale
Dierolf, M., Menzel, A., Thibault, P., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O., & Pfeiffer, F. (2010) · Nature · doi:10.1038/nature09419 · Cited by 926
Bordiga, S., Groppo, E., Agostini, G., van Bokhoven, J. A., & Lamberti, C. (2013) · Chemical Reviews · doi:10.1021/cr2000898 · Cited by 643
Liu, Y., Meirer, F., Williams, P. A., Wang, J., Andrews, J. C., & Pianetta, P. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511049144 · Cited by 278
Self-citationGuan, Y., Gong, Y., Li, W., Gelb, J., Zhang, L., Liu, G., Zhang, X., Song, X., Xia, C., Xiong, Y., et al. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.08.083 · Cited by 59
Metadata
- Authors
- Chu, Y. S., Yi, J. M., De Carlo, F., Shen, Q., Lee, W.-K., Wu, H. J., Wang, C. L., Wang, J. Y., Liu, C. J., Wang, C. H., Wu, S. R., Chien, C. C., Hwu, Y., Tkachuk, A., Yun, W., Feser, M., Liang, K. S., Yang, C. S., Je, J. H., & Margaritondo, G.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2008-03-10
- Volume
- 92
- Issue
- 10
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2011156041
- Cited by
- 184
- References
- 1
- FWCI
- 19.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hard-x-ray microscopy with Fresnel zone plates reaches 40nm Rayleigh resolution. https://app.cochat.ai/papers/10.1063/1.2857476
- The paper
- Chu, Y. S., Yi, J. M., De Carlo, F., Shen, Q., Lee, W.-K., Wu, H. J., Wang, C. L., Wang, J. Y., Liu, C. J., Wang, C. H., Wu, S. R., Chien, C. C., Hwu, Y., Tkachuk, A., Yun, W., Feser, M., Liang, K. S., Yang, C. S., Je, J. H., & Margaritondo, G. (2008). Hard-x-ray microscopy with Fresnel zone plates reaches 40nm Rayleigh resolution. Applied Physics Letters. https://doi.org/10.1063/1.2857476
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.