The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Effect of sample size on deformation in amorphous metals
Abstract
Uniaxial compression tests were performed on micron-sized columns of amorphous PdSi to investigate the effect of sample size on deformation behavior. Cylindrical columns with diameters between 8μm and 140nm were fabricated from sputtered amorphous Pd77Si23 films on Si substrates by focused ion beam machining and compression tests were performed with a nanoindenter outfitted with a flat diamond punch. The columns exhibited elastic behavior until they yielded by either shear band formation on a plane at 50° to the loading axis or by homogenous deformation. Shear band formation occurred only in columns with diameters larger than 400nm. The change in deformation mechanism from shear band formation to homogeneous deformation with decreasing column size is attributed to a required critical strained volume for shear band formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
A microscopic mechanism for steady state inhomogeneous flow in metallic glasses
Spaepen, F. (1977) · Acta Metallurgica · doi:10.1016/0001-6160(77)90232-2 · Cited by 2,933
Self-citationPlastic deformation in metallic glasses
Argon, A. S. (1979) · Acta Metallurgica · doi:10.1016/0001-6160(79)90055-5 · Cited by 2,720
Sample Dimensions Influence Strength and Crystal Plasticity
Uchic, M. D., Dimiduk, D. M., Florando, J. N., & Nix, W. D. (2004) · Science · doi:10.1126/science.1098993 · Cited by 2,330
Size effects in the deformation of sub-micron Au columns
Volkert, C. A., & Lilleodden, E. T. (2006) · Philosophical Magazine · doi:10.1080/14786430600567739 · Cited by 727
Self-citationTensile ductility and necking of metallic glass
Guo, H., Yan, P., Wang, Y. B., Tan, J., Zhang, Z. F., Sui, M., & Ma, E. (2007) · Nature Materials · doi:10.1038/nmat1984 · Cited by 565
The design of accurate micro-compression experiments
Zhang, H., Schuster, B. E., Wei, Q., & Ramesh, K. T. (2006) · Scripta Materialia · doi:10.1016/j.scriptamat.2005.06.043 · Cited by 436
Young's modulus and internal friction in metallic glass alloys from 1.5 to 300 K
Barmatz, M. B., & Chen, H. S. (1974) · Physical review. B, Solid state · doi:10.1103/physrevb.9.4073 · Cited by 84
A study of turbulent combustion and its modeling using a diffusion reaction equation model
Girimaji, S. S. (1996) · International Journal of Engineering Science · doi:10.1016/0020-7225(95)00076-3 · Cited by 35
Cited by
Plasticity in small-sized metallic systems: Intrinsic versus extrinsic size effect
Greer, J. R., & De Hosson, J. T. M. (2011) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.01.005 · Cited by 1,763
The elastic properties, elastic models and elastic perspectives of metallic glasses
Wang, W. H. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.07.001 · Cited by 1,362
Processing of Bulk Metallic Glass
Schroers, J. (2010) · Advanced Materials · doi:10.1002/adma.200902776 · Cited by 1,030
Plasticity of Micrometer-Scale Single Crystals in Compression
Uchic, M. D., Shade, P. A., & Dimiduk, D. M. (2009) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-082908-145422 · Cited by 770
Jang, D., & Greer, J. R. (2010) · Nature Materials · doi:10.1038/nmat2622 · Cited by 722
Metadata
- Authors
- Volkert, C. A., Donohue, A., & Spaepen, F.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2008-04-15
- Volume
- 103
- Issue
- 8
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2056569954
- Cited by
- 430
- References
- 9
- FWCI
- 57.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.