The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
A broadband Fourier transform microwave spectrometer based on chirped pulse excitation
Abstract
Designs for a broadband chirped pulse Fourier transform microwave (CP-FTMW) spectrometer are presented. The spectrometer is capable of measuring the 7–18GHz region of a rotational spectrum in a single data acquisition. One design uses a 4.2Gsamples∕s arbitrary waveform generator (AWG) to produce a 1μs duration chirped pulse with a linear frequency sweep of 1.375GHz. This pulse is sent through a microwave circuit to multiply the bandwidth of the pulse by a factor of 8 and upconvert it to the 7.5–18.5GHz range. The chirped pulse is amplified by a traveling wave tube amplifier and broadcast inside the spectrometer by using a double ridge standard gain horn antenna. The broadband molecular free induction decay (FID) is received by a second horn antenna, downconverted, and digitized by a 40Gsamples∕s (12GHz hardware bandwidth) digital oscilloscope. The second design uses a simplified pulse generation and FID detection scheme, employing current state-of-the-art high-speed digital electronics. In this spectrometer, a chirped pulse with 12GHz of bandwidth is directly generated by using a 20Gsamples∕s AWG and upconverted in a single step with an ultrabroadband mixer. The amplified molecular emission is directly detected by using a 50Gsamples∕s digital oscilloscope with 18GHz bandwidth. In both designs, fast Fourier transform of the FID produces the frequency domain rotational spectrum in the 7–18GHz range. The performance of the CP-FTMW spectrometer is compared to a Balle–Flygare–type cavity-FTMW spectrometer. The CP-FTMW spectrometer produces an equal sensitivity spectrum with a factor of 40 reduction in measurement time and a reduction in sample consumption by a factor of 20. The CP-FTMW spectrometer also displays good intensity accuracy for both sample number density and rotational transition moment. Strategies to reduce the CP-FTMW measurement time by another factor of 90 while simultaneously reducing the sample consumption by a factor of 30 are demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical resonance and two-level atoms
Allen, L., & Eberly, J. H. (1975) · Cited by 2,614
NMR Spectroscopy: Basic Principles, Concepts and Applications in Chemistry
Günther, H. (2013) · Cited by 540
Handbook of digital signal processing: engineering applications
(1988) · Choice Reviews Online · doi:10.5860/choice.26-0940 · Cited by 163
Microwave spectrum and rotational isomerism of ethyl nitrate
Scroggin, D. G., Riveros, J. M., & Wilson, E. B. (1974) · The Journal of Chemical Physics · doi:10.1063/1.1681207 · Cited by 39
Two-dimensional correlation experiments in microwave Fourier transform spectroscopy
Vogelsanger, B., Andrist, M., & BAUDER, A. (1988) · Chemical Physics Letters · doi:10.1016/0009-2614(88)87113-6 · Cited by 26
Two-dimensional Fourier transform spectroscopy in the microwave-radiofrequency range
Jäger, W., Haekel, J., Andresen, U., et al. (1989) · Molecular Physics · doi:10.1080/00268978900102911 · Cited by 17
Cited by
Cavallo, G., Metrangolo, P., Milani, R., Pilati, T., Priimagi, A., Resnati, G., & Terraneo, G. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00484 · Cited by 4,035
Enantiomer-specific detection of chiral molecules via microwave spectroscopy
Patterson, D., Schnell, M., & Doyle, J. M. (2013) · Nature · doi:10.1038/nature12150 · Cited by 490
Concerted hydrogen-bond breaking by quantum tunneling in the water hexamer prism
Richardson, J. O., Pérez, C., Lobsiger, S., Reid, A. A., Temelso, B., Shields, G. C., Kisiel, Z., Wales, D. J., Pate, B. H., & Althorpe, S. C. (2016) · Science · doi:10.1126/science.aae0012 · Cited by 346
Self-citationBroadband Fourier transform rotational spectroscopy for structure determination: The water heptamer
Pérez, C., Lobsiger, S., Seifert, N. A., Zaleski, D. P., Temelso, B., Shields, G. C., Kisiel, Z., & Pate, B. H. (2013) · Chemical Physics Letters · doi:10.1016/j.cplett.2013.04.014 · Cited by 264
Self-citationDETECTION OF E-CYANOMETHANIMINE TOWARD SAGITTARIUS B2(N) IN THE GREEN BANK TELESCOPE PRIMOS SURVEY
Zaleski, D. P., Seifert, N. A., Steber, A. L., Muckle, M. T., Loomis, R. A., Corby, J. F., Martinez, O., Crabtree, K. N., Jewell, P. R., Hollis, J. M., et al. (2013) · The Astrophysical Journal · doi:10.1088/2041-8205/765/1/l10 · Cited by 133
Self-citation
Metadata
- Authors
- Brown, G. G., Dian, B. C., Douglass, K. O., Geyer, S. M., Shipman, S. T., & Pate, B. H.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2008-05-01
- Volume
- 79
- Issue
- 5
- Pages
- 053103-053103
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2012683273
- Cited by
- 634
- References
- 6
- FWCI
- 7.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.