CoChat

Wideband low-noise optical beam deflection sensor with photothermal excitation for liquid-environment atomic force microscopy

Open access
Fukuma, Takeshi · 2009 · Review of Scientific Instruments
Cited by 142

The DOI matches its Crossref record.

Abstract

I developed a wideband low-noise optical beam deflection sensor with a photothermal cantilever excitation system for liquid-environment atomic force microscopy. The developed sensor has a 10 MHz bandwidth and 4.7 fm/Hz deflection noise density in water. The theoretically limited noise performance (i.e., the noise level limited only by the photodiode shot noise) has been achieved in liquid for the first time. Owing to the wide bandwidth and the replaceable focus lens design, the sensor is applicable to cantilevers with various dimensions. The deflection noise densities of less than 7.8 fm/Hz have been achieved in water for cantilevers with lengths from 35 to 125 μm. The ideal amplitude and phase versus frequency curves without distortion are obtained with the developed photothermal excitation system. The excitation system is applicable to relatively stiff cantilevers (>20 N/m) in liquid, making it possible to obtain true atomic-resolution images in liquid. True atomic-resolution imaging of mica in water is demonstrated using the developed deflection sensor and the photothermal excitation system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.3086418

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Fukuma, T.
Venue
Review of Scientific Instruments
Published
2009-02-01
Volume
80
Issue
2
Pages
023707-023707
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W1986037089
Cited by
142
References
0
FWCI
3.90
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.