The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Beamline I11 at Diamond: A new instrument for high resolution powder diffraction
Abstract
The performance characteristics of a new synchrotron x-ray powder diffraction beamline (I11) at the Diamond Light Source are presented. Using an in-vacuum undulator for photon production and deploying simple x-ray optics centered around a double-crystal monochromator and a pair of harmonic rejection mirrors, a high brightness and low bandpass x-ray beam is delivered at the sample. To provide fast data collection, 45 Si(111) analyzing crystals and detectors are installed onto a large and high precision diffractometer. High resolution powder diffraction data from standard reference materials of Si, α-quartz, and LaB6 are used to characterize instrumental performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fundamental parameters approach to X-ray line-profile fitting
Cheary, R. W., & Coelho, A. (1992) · Journal of Applied Crystallography · doi:10.1107/s0021889891010804 · Cited by 1,660
Handbook on Synchrotron Radiation
(1987) · Elsevier eBooks · doi:10.1016/c2009-0-09951-6 · Cited by 1,246
Handbook on Synchrotron Radiation
Codling, K. (1992) · Journal of Modern Optics · doi:10.1080/09500349214550911 · Cited by 466
Cited by
Keshavarz, M., Debroye, E., Ottesen, M., Martin, C., Zhang, H., Fron, E., Küchler, R., Steele, J. A., Bremholm, M., Van de Vondel, J., et al. (2020) · Advanced Materials · doi:10.1002/adma.202001878 · Cited by 618
Selectivity and direct visualization of carbon dioxide and sulfur dioxide in a decorated porous host
Yang, S., Sun, J., Ramirez-Cuesta, A. J., Callear, S. K., David, W. I. F., Anderson, D. P., Newby, R., Blake, A. J., Parker, J. E., Tang, C. C., et al. (2012) · Nature Chemistry · doi:10.1038/nchem.1457 · Cited by 554
Self-citationControl of zeolite pore interior for chemoselective alkyne/olefin separations
Chai, Y., Han, X., Li, W., Liu, S., Yao, S., Wang, C., Shi, W., da-Silva, I., Manuel, P., Cheng, Y., et al. (2020) · Science · doi:10.1126/science.aay8447 · Cited by 372
Self-citationKawaguchi, S., Takemoto, M., Osaka, K., Nishibori, E., Moriyoshi, C., Kubota, Y., Kuroiwa, Y., & Sugimoto, K. (2017) · Review of Scientific Instruments · doi:10.1063/1.4999454 · Cited by 358
Foo, C., Li, Y., Lebedev, K., Chen, T., Day, S., Tang, C., & Tsang, S. C. E. (2021) · Nature Communications · doi:10.1038/s41467-021-20977-z · Cited by 273
Self-citation
Metadata
- Authors
- Thompson, S. P., Parker, J. E., Potter, J., Hill, T. P., Birt, A., Cobb, T. M., Yuan, F., & Tang, C. C.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2009-07-01
- Volume
- 80
- Issue
- 7
- Pages
- 075107-075107
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2005073755
- Cited by
- 349
- References
- 3
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).