The DOI matches its Crossref record.
Calibration of the pressure dependence of the R 1 ruby fluorescence line to 195 kbar
Abstract
The pressure dependence of the R1 ruby fluorescence line has been calibrated at 25 °C against the compression of NaCl. Pressures are determined using the Decker equation of state for NaCl. The dependence is linear to 195 kbar following the equation PNaCl=2.746(Δλ), where P is in kbar and Δλ in Å. The uncertainty in the value of the slope, dp/dλ, expressed in terms of a 95% confidence interval is 2.746±0.014 kbar Å−1. The coefficient of the quadratic term (Δλ)2 is not significantly different from zero; and the quadratic term makes indeed a negligible contribution to the fit. Taking into account the reported uncertainty associated with the Decker equation of state for NaCl, the value of the slope is 2.740±0.016 kbar Å−1 within a 95% confidence interval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raman scattering and phonon dispersion in Si and GaP at very high pressure
Weinstein, B. A., & Piermarini, G. J. (1975) · Physical Review B · doi:10.1103/physrevb.12.1172 · Cited by 490
Self-citationKasem, M. R., Nakahira, Y., Yamaoka, H., Matsumoto, R., Yamashita, A., Ishii, H., Hiraoka, N., Takano, Y., Goto, Y., & Mizuguchi, Y. (2022) · Scientific Reports · doi:10.1038/s41598-022-11862-w · Cited by 35
Metadata
- Authors
- Piermarini, G. J., Block, S., Barnett, J. D., & Forman, R. A.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1975-06-01
- Volume
- 46
- Issue
- 6
- Pages
- 2774-2780
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1969749365
- Cited by
- 2,038
- References
- 0
- FWCI
- 21.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of the pressure dependence of the R 1 ruby fluorescence line to 195 kbar. https://app.cochat.ai/papers/10.1063/1.321957
- The paper
- Piermarini, G. J., Block, S., Barnett, J. D., & Forman, R. A. (1975). Calibration of the pressure dependence of the R 1 ruby fluorescence line to 195 kbar. Journal of Applied Physics. https://doi.org/10.1063/1.321957
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.