CoChat

The calibration of the strength of the localized vibrational modes of silicon impurities in epitaxial GaAs revealed by infrared absorption and Raman scattering

Murray, R., Newman, R. C., Sangster, M. J. L., Beall, R. B., Harris, J. J., Wright, P. J., Wagner, J., Ramsteiner, M. · 1989 · Journal of Applied Physics
Cited by 152

The DOI matches its Crossref record.

Abstract

n-type silicon-doped epitaxial layers of gallium arsenide grown by molecular-beam epitaxy (MBE) or metal-organo chemical vapor deposition (MOCVD) have been investigated by measurements of the Hall effect and the strengths of the localized vibrational modes (LVM) of silicon impurities using both Fourier transform absorption spectroscopy and Raman scattering at an excitation energy of 3 eV close to the E1 band gap. Lines from Si(Ga) donors, Si(As) acceptors, Si(Ga)-Si(As) pairs, and Si-X, a complex of silicon with a native defect, were detected and correlated for the two techniques. The maximum carrier concentration [n] found for samples grown under standard conditions was 5.5×1018 cm−3. At higher doping levels Si-X becomes dominant and acts as an acceptor, so reducing [n]. An integrated absorption of 1 cm−2 in the Si(Ga) LVM line corresponds to 5.0±4×1016 atoms cm−3: a similar calibration applies to the Si(As) line, but for Si-X, an absorption of 1 cm−2 corresponds to only 2.7±1.0×1016 defects cm−3. Possible structures for Si-X are discussed but a definitive model cannot yet be proposed. MBE samples grown at 400 °C had values of [n] close to 1019 cm−3, and a negligible concentration of Si-X. On annealing, [n] decreased and Si-X defects were produced together with site switching of Si(Ga) to Si(As). These results are important to the understanding of the mechanism of silicon diffusion at low temperatures. The infrared absorption and Raman measurements are complementary. Absorption measurements made at a resolution of 0.1 cm−1 require layers greater than or equal to 1 μm in thickness doped to a level of 3×1017 cm−3 but require the prior elimination of free-carrier absorption. Raman measurements can be made on as-grown layers only 10 nm in thickness doped to a level of 2×1018 cm−3, but with a spectral resolution of only 5 cm−1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.344224

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 152

Metadata

Authors
Murray, R., Newman, R. C., Sangster, M. J. L., Beall, R. B., Harris, J. J., Wright, P. J., Wagner, J., & Ramsteiner, M.
Venue
Journal of Applied Physics
Published
1989-09-15
Volume
66
Issue
6
Pages
2589-2596
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2016643276
Cited by
152
References
0
FWCI
5.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The calibration of the strength of the localized vibrational modes of silicon impurities in epitaxial GaAs revealed by infrared absorption and Raman scattering. https://app.cochat.ai/papers/10.1063/1.344224
The paper
Murray, R., Newman, R. C., Sangster, M. J. L., Beall, R. B., Harris, J. J., Wright, P. J., Wagner, J., & Ramsteiner, M. (1989). The calibration of the strength of the localized vibrational modes of silicon impurities in epitaxial GaAs revealed by infrared absorption and Raman scattering. Journal of Applied Physics. https://doi.org/10.1063/1.344224

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.