The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Coherent millimeter-wave generation by heterodyne conversion in low-temperature-grown GaAs photoconductors
Abstract
An analysis has been carried out of optical heterodyne conversion with an interdigitated-electrode photomixer made from low-temperature-grown (LTG) GaAs and pumped by two continuous-wave, frequency-offset pump lasers. The analytic prediction is in excellent agreement with the experimental results obtained recently on a photomixer having 1.0-μm-wide electrodes and gaps. The analysis predicts that a superior photomixer having 0.2-μm-wide electrodes and gaps would have a temperature-limited conversion efficiency of 2.0% at a low difference frequency, 1.6% at 94 GHz, and 0.5% at 300 GHz when connected to a broadband 100 Ω load resistance and pumped at hν=2.0 eV by a total optical power of 50 mW. The predicted 3-dB bandwidth (193 GHz) of this photomixer is limited by both the electron-hole recombination time (0.6 ps) of the LTG-GaAs material and the RC time constant (0.5 ps) of the photomixer circuit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconducting and other major properties of gallium arsenide
Blakemore, J. S. (1982) · Journal of Applied Physics · doi:10.1063/1.331665 · Cited by 2,503
Optical generation, distribution, and control of microwaves using laser heterodyne
Simonis, G. J., & Purchase, K. G. (1990) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.54938 · Cited by 143
External electro-optic integrated circuit probing
Whitaker, J. F., Valdmanis, J. A., Frankel, M. Y., Gupta, S. K., Chwalek, J. M., & Mourou, G. A. (1990) · Microelectronic Engineering · doi:10.1016/0167-9317(90)90050-4 · Cited by 27
Cited by
Siegel, P. H. (2002) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.989974 · Cited by 3,045
Terahertz spectroscopy and imaging - Modern techniques and applications
Jepsen, P. U., Cooke, D. G., & Koch, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000011 · Cited by 2,091
Biomedical applications of terahertz technology
Pickwell, E., & Wallace, V. P. (2006) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/39/17/r01 · Cited by 925
Terahertz Spectroscopy and Imaging for Defense and Security Applications
Liu, H.-B., Zhong, H., Karpowicz, N., Chen, Y., & Zhang, X.-C. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.898903 · Cited by 636
Terahertz fields and applications
Dragoman, D., & Dragoman, M. (2004) · Progress in Quantum Electronics · doi:10.1016/s0079-6727(03)00058-2 · Cited by 499
Metadata
- Authors
- Brown, E. R., Smith, F. W., & McIntosh, K. A.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1993-02-01
- Volume
- 73
- Issue
- 3
- Pages
- 1480-1484
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1995731749
- Cited by
- 355
- References
- 3
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.