Evaporation rate of water in a vessel
The DOI matches its Crossref record.
Abstract
The evaporation rate of water in a vessel was studied as a function of of temperature, humidity, air velocity, and diameter of the vessel. The atmospheric temperature was varied between 14 and 29 °C, the humidity between 24% and 75%, the air velocity between 0.09 and 7.9 m/s, and the diameter between 5.6 and 12.4 cm. The experimental results are compared with a theory that is based on the idea that the evaporation rate is equal to the diffusion rate of water vapor through the boundary layer covering the water surface in a vessel. In order to compare the experimental evaporation rate with the theory, the temperature of the water surface was carefully measured with a thin thermocouple. The agreement between the present experiments and the theory is generally good.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Solar-driven interfacial evaporation
Tao, P., Ni, G., Song, C., Shang, W., Wu, J., Zhu, J., Chen, G., & Deng, T. (2018) · Nature Energy · doi:10.1038/s41560-018-0260-7 · Cited by 2,380
Contact line deposits in an evaporating drop
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (2000) · Physical Review E · doi:10.1103/physreve.62.756 · Cited by 2,300
The International Workshop on Meibomian Gland Dysfunction: Report of the Diagnosis Subcommittee
Tomlinson, A., Bron, A. J., Korb, D. R., Amano, S., Paugh, J. R., Pearce, E. I., Yee, R., Yokoi, N., Arita, R., & Dogru, M. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6997f · Cited by 855
A review on inkjet printing of nanoparticle inks for flexible electronics
Nayak, L., Mohanty, S., Nayak, S. K., & Ramadoss, A. (2019) · Journal of Materials Chemistry C · doi:10.1039/c9tc01630a · Cited by 497
Metadata
- Authors
- Hisatake, K., Tanaka, S., & Aizawa, Y.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1993-06-01
- Volume
- 73
- Issue
- 11
- Pages
- 7395-7401
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2068859019
- Cited by
- 146
- References
- 0
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaporation rate of water in a vessel. https://app.cochat.ai/papers/10.1063/1.354031
- The paper
- Hisatake, K., Tanaka, S., & Aizawa, Y. (1993). Evaporation rate of water in a vessel. Journal of Applied Physics. https://doi.org/10.1063/1.354031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.