Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record.

Picosecond optical studies of amorphous diamond and diamondlike carbon: Thermal conductivity and longitudinal sound velocity

Morath, Christopher J., Maris, Humphrey J., Cuomo, Jerome J., Pappas, David L., Grill, Alfred, Patel, Vishnubhai V., Doyle, James P., Saenger, Katherine L. · 1994 · Journal of Applied Physics

Abstract

A picosecond pump-probe technique is used to measure the room-temperature thermal conductivity κ and longitudinal sound velocity cl of amorphous diamond (a-D) and diamondlike carbon (DLC) thin films. Both κ and cl were found to decrease with film hydrogen content. Depending on the film deposition technique, κ is in the range 5–10×10−2 W cm−1 K−1 for a-D, and 3–10×10−3 W cm−1 K−1 for DLC. Values of cl were found to be in the range 14–18×105 cm s−1 for a-D, and 6–9×105 cm s−1 for DLC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.357560

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 209

Metadata

Authors
Morath, C. J., Maris, H. J., Cuomo, J. J., Pappas, D. L., Grill, A., Patel, V. V., Doyle, J. P., & Saenger, K. L.
Venue
Journal of Applied Physics
Published
1994-09-01
Volume
76
Issue
5
Pages
2636-2640
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2080800672
Cited by
209
References
0
FWCI
4.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Picosecond optical studies of amorphous diamond and diamondlike carbon: Thermal conductivity and longitudinal sound velocity. https://app.cochat.ai/papers/10.1063/1.357560
The paper
Morath, C. J., Maris, H. J., Cuomo, J. J., Pappas, D. L., Grill, A., Patel, V. V., Doyle, J. P., & Saenger, K. L. (1994). Picosecond optical studies of amorphous diamond and diamondlike carbon: Thermal conductivity and longitudinal sound velocity. Journal of Applied Physics. https://doi.org/10.1063/1.357560

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.