Comparison of photothermal and piezoacoustic excitation methods for frequency and phase modulation atomic force microscopy in liquid environments
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In attempting to perform frequency modulation atomic force microscopy (FM-AFM) in liquids, a non-flat phase transfer function in the self-excitation system prevents proper tracking of the cantilever natural frequency. This results in frequency-and-phase modulation atomic force microscopy (FPM-AFM) which lies in between phase modulation atomic force microscopy (PM-AFM) and FM-AFM. We derive the theory necessary to recover the conservative force and damping in such a situation, where standard FM-AFM theory no longer applies. Although our recovery procedure applies to all cantilever excitation methods in principle, its practical implementation may be difficult, or even impossible, if the cantilever is driven piezoacoustically. Specifically, we contrast the piezoacoustic excitation method to the photothermal method in the context of force spectroscopy of hydration structures at the mica-water interface. The results clearly demonstrate that photothermal excitation is superior to piezoacoustic excitation, as it allows for accurate quantitative interpretation of the acquired data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fukuma, T., Ueda, Y., Yoshioka, S., & Asakawa, H. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.016101 · Cited by 464
Cited by
Atomic- and Molecular-Resolution Mapping of Solid–Liquid Interfaces by 3D Atomic Force Microscopy
Fukuma, T., & Garcia, R. (2018) · ACS Nano · doi:10.1021/acsnano.8b07216 · Cited by 198
Atomic-scale mapping of hydrophobic layers on graphene and few-layer MoS2 and WSe2 in water
Uhlig, M. R., Martin-Jimenez, D., & Garcia, R. (2019) · Nature Communications · doi:10.1038/s41467-019-10740-w · Cited by 138
Monotonic Damping in Nanoscopic Hydration Experiments
Labuda, A., Kobayashi, K., Suzuki, K., Yamada, H., & Grütter, P. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.066102 · Cited by 38
Self-citation
Metadata
- Authors
- Labuda, A., Kobayashi, K., Kiracofe, D., Suzuki, K., Grütter, P. H., & Yamada, H.
- Venue
- AIP Advances
- Publisher
- AIP Publishing
- Published
- 2011-06-01
- Volume
- 1
- Issue
- 2
- ISSN
- 2158-3226 (ISSN-L)
- OpenAlex
- W1985256336
- Cited by
- 75
- References
- 1
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of photothermal and piezoacoustic excitation methods for frequency and phase modulation atomic force microscopy in liquid environments. https://app.cochat.ai/papers/10.1063/1.3601872
- The paper
- Labuda, A., Kobayashi, K., Kiracofe, D., Suzuki, K., Grütter, P. H., & Yamada, H. (2011). Comparison of photothermal and piezoacoustic excitation methods for frequency and phase modulation atomic force microscopy in liquid environments. AIP Advances. https://doi.org/10.1063/1.3601872
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.