The DOI matches its Crossref record.
Separation of platelets from other blood cells in continuous-flow by dielectrophoresis field-flow-fractionation
Open accessAbstract
We present a microfluidic device capable of separating platelets from other blood cells in continuous flow using dielectrophoresis field-flow-fractionation. The use of hydrodynamic focusing in combination with the application of a dielectrophoretic force allows the separation of platelets from red blood cells due to their size difference. The theoretical cell trajectory has been calculated by numerical simulations of the electrical field and flow speed, and is in agreement with the experimental results. The proposed device uses the so-called “liquid electrodes” design and can be used with low applied voltages, as low as 10 Vpp. The obtained separation is very efficient, the device being able to achieve a very high purity of platelets of 98.8% with less than 2% cell loss. Its low-voltage operation makes it particularly suitable for point-of-care applications. It could further be used for the separation of other cell types based on their size difference, as well as in combination with other sorting techniques to separate multiple cell populations from each other.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Isolation of Circulating Tumor Cells by Dielectrophoresis
Gascoyne, P., & Shim, S. (2014) · Cancers · doi:10.3390/cancers6010545 · Cited by 275
A Theoretical Analysis of the Effects of Tumor-Treating Electric Fields on Single Cells
Li, X., Yang, F., Gao, B., Yu, X., & Rubinsky, B. (2020) · Bioelectromagnetics · doi:10.1002/bem.22274 · Cited by 16
Metadata
- Authors
- Piacentini, N., Mernier, G., Tornay, R., & Renaud, P.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2011-09-01
- Volume
- 5
- Issue
- 3
- Pages
- 34122-341228
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2043069729
- Cited by
- 177
- References
- 0
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of platelets from other blood cells in continuous-flow by dielectrophoresis field-flow-fractionation. https://app.cochat.ai/papers/10.1063/1.3640045
- The paper
- Piacentini, N., Mernier, G., Tornay, R., & Renaud, P. (2011). Separation of platelets from other blood cells in continuous-flow by dielectrophoresis field-flow-fractionation. Biomicrofluidics. https://doi.org/10.1063/1.3640045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.