The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Injector for scattering measurements on fully solvated biospecies
Abstract
We describe a liquid jet injector system developed to deliver fully solvated microscopic target species into a probe beam under either vacuum or ambient conditions. The injector was designed specifically for x-ray scattering studies of biological nanospecies using x-ray free electron lasers and third generation synchrotrons, but is of interest to any application in which microscopic samples must be delivered in a fully solvated state and with microscopic precision. By utilizing a gas dynamic virtual nozzle (GDVN) to generate a sample-containing liquid jet of diameter ranging from 300 nm to 20 μm, the injector avoids the clogging problems associated in this size range with conventional Rayleigh jets. A differential pumping system incorporated into the injector shields the experimental chamber from the gas load of the GDVN, making the injector compatible with high vacuum systems. The injector houses a fiber-optically coupled pump laser to illuminate the jet for pump-probe experiments and a hermetically sealed microscope to observe the liquid jet for diagnostics and alignment during operation. This injector system has now been used during several experimental runs at the Linac Coherent Light Source. Recent refinements in GDVN design are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Cited by
Structure of the toxic core of α-synuclein from invisible crystals
Rodriguez, J. A., Ivanova, M. I., Sawaya, M. R., Cascio, D., Reyes, F. E., Shi, D., Sangwan, S., Guenther, E. L., Johnson, L. M., Zhang, M., et al. (2015) · Nature · doi:10.1038/nature15368 · Cited by 619
Linac Coherent Light Source: The first five years
Bostedt, C., Boutet, S., Fritz, D. M., Huang, Z., Lee, H. J., Lemke, H. T., Robert, A., Schlotter, W. F., Turner, J. J., & Williams, G. J. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.015007 · Cited by 618
Lipidic cubic phase injector facilitates membrane protein serial femtosecond crystallography
Weierstall, U., James, D., Wang, C., White, T. A., Wang, D., Liu, W., Spence, J. C. H., Bruce Doak, R., Nelson, G., Fromme, P., et al. (2014) · Nature Communications · doi:10.1038/ncomms4309 · Cited by 583
Self-citationTenboer, J., Basu, S., Zatsepin, N., Pande, K., Milathianaki, D., Frank, M., Hunter, M., Boutet, S., Williams, G. J., Koglin, J. E., et al. (2014) · Science · doi:10.1126/science.1259357 · Cited by 508
Self-citationSerial time-resolved crystallography of photosystem II using a femtosecond X-ray laser
Kupitz, C., Basu, S., Grotjohann, I., Fromme, R., Zatsepin, N. A., Rendek, K. N., Hunter, M. S., Shoeman, R. L., White, T. A., Wang, D., et al. (2014) · Nature · doi:10.1038/nature13453 · Cited by 477
Self-citation
Metadata
- Authors
- Weierstall, U., Spence, J. C. H., & Doak, R. B.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2012-03-01
- Volume
- 83
- Issue
- 3
- Pages
- 035108-035108
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2050444770
- Cited by
- 225
- References
- 1
- FWCI
- 24.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Injector for scattering measurements on fully solvated biospecies. https://app.cochat.ai/papers/10.1063/1.3693040
- The paper
- Weierstall, U., Spence, J. C. H., & Doak, R. B. (2012). Injector for scattering measurements on fully solvated biospecies. Review of Scientific Instruments. https://doi.org/10.1063/1.3693040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.