CoChat

Terahertz radiation imaging of supercurrent distribution in vortex-penetrated YBa2Cu3O7−δ thin film strips

Tonouchi, Masayoshi, Yamashita, Masatsugu, Hangyo, Masanori · 2000 · Journal of Applied Physics
Cited by 67

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We have developed a supercurrent distribution imaging system for high Tc superconductive thin films and demonstrated the visualization of the supercurrent distribution in the vortex-penetrated YBa2Cu3O7−δ thin film strips. The terahertz (THz) radiation and detection system with a scanning femtosecond laser was employed to visualize the distribution. The imaging system utilizes the principle that the femtosecond optical pulses excite THz radiation into the free space by optical supercurrent modulation, and the radiation amplitude is proportional to the local supercurrent density at the optically excited area. Prior to the observation of the supercurrent distribution, we studied optical excitation effects on the vortices trapped in the strips, calibration of the current density from the THz radiation amplitude, temperature dependence of the THz radiation properties, etc. The laser power dependence of the THz radiation in the remanent state revealed that the excitation with powers larger than the relatively weak finite value (about 10 mW in the present case) strongly affects the vortices trapped in the films. We attributed this behavior to the optically excited depinning effect. We derived a calibration function from the THz radiation images into the supercurrent density distributions by observing the bias-current dependence of the THz radiation, and applied it for the diagnosis of the distributions in the vortex-penetrated strips. The THz radiation images were successfully transferred into the supercurrent density distributions with quantitative agreement. The minimum magnetic flux resolution at the optically excited area was roughly estimated to be 3 φ0 where φ0 is a single flux quantum. The measurement of the laser beam profile indicated that the spatial resolution of the THz radiation images is limited by the laser beam diameter: 25 μm in our case. The observed distributions revealed that the vortices easily penetrate into the strip under an external magnetic field BEX of 0.9 mT, and the persistent supercurrent exists only near the strip edges in the remanent state after removal of the field. The calculations of the convolution between the observed laser pattern and the trial functions suggested that the supercurrent distribution width in the remanent state after removal of the field of 0.9 mT is estimated to be less than 1 μm. The temperature dependence of the supercurrent distributions revealed that, below 60 K, the thermal activation produces no significant effects on the penetrated vortices at BEX=0.9 mT, whereas, the vortices in the remanent state after removal of the field of 15 mT were strongly affected by the thermal activation. The decreasing rate of the supercurrent density at the edge with increasing temperature was larger than that inside the strip. This suggested that the vortices trapped near the edges exhibit rather different behavior from the ones that penetrated into the inner part of the strip.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.372995

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 67

Metadata

Authors
Tonouchi, M., Yamashita, M., & Hangyo, M.
Venue
Journal of Applied Physics
Published
2000-05-15
Volume
87
Issue
10
Pages
7366-7375
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2020229743
Cited by
67
References
2
FWCI
6.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.