Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 378

The DOI matches its Crossref record.

Rotational diffusion studied by passage saturation transfer electron paramagnetic resonance

Thomas, David D., Dalton, Larry R., Hyde, James S.·1976·The Journal of Chemical Physics

Abstract

A comprehensive description is given of instrumental and theoretical methods employed to make accurate measurements of rotational correlation times using passage saturation transfer electron paramagnetic resonance (ST–EPR). Saturation transfer methods extend by several orders of magnitude the sensitivity of EPR to very slow motion; for example, for nitroxide spin labels, correlation times as long as 10−3 sec become accessible to measurement. Two ST–EPR detection schemes are discussed in detail: dispersion, detected 90° out of phase with respect to the 100 kHz field modulation, and absorption, detected 90° out of phase with respect to the second harmonic of the 50 kHz field modulation. The sensitivities of these configurations are illustrated with experimental spectra obtained from a system obeying isotropic Brownian rotational diffusion; namely, maleimide spin labeled human oxyhemoglobin in aqueous glycerol solutions. Two theoretical approaches, one employing coupled Bloch equations and the other utilizing the stochastic Liouville equation for the density matrix with the orientation variables treated by transition rate matrix or orthogonal eigenfunction expansion methods, are in excellent agreement with each other and with model system spectra. Both experimental and theoretical spectra depend on a number of relaxation processes other than rotational diffusion; consequently, considerable care must be taken to ensure the accuracy of measured rotational correlation times. Although the absorption method is currently the more sensitive and convenient one to apply with most conventional (commercial) spectrometers, the dispersion ST–EPR method is potentially more powerful, providing strong motivation for future technological efforts to decrease noise levels in dispersion experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.433512

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 378

Metadata

Authors
Thomas, D. D., Dalton, L. R., & Hyde, J. S.
Venue
The Journal of Chemical Physics
Published
1976-10-15
Volume
65
Issue
8
Pages
3006-3024
ISSN
  • 0021-9606 (ISSN-L)
  • 1089-7690
OpenAlex
W1989650576
Cited by
378
References
0
FWCI
14.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rotational diffusion studied by passage saturation transfer electron paramagnetic resonance. https://app.cochat.ai/papers/10.1063/1.433512
The paper
Thomas, D. D., Dalton, L. R., & Hyde, J. S. (1976). Rotational diffusion studied by passage saturation transfer electron paramagnetic resonance. The Journal of Chemical Physics. https://doi.org/10.1063/1.433512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.