The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Charge reversal seen in electrical double layer interaction of surfaces immersed in 2:1 calcium electrolyte
Abstract
Interactions between charged surfaces immersed in aqueous calcium solutions were measured using the surface force apparatus and the atomic force microscope. With the surface force apparatus, good agreement with previously reported measurements was found for mica surfaces in dilute solutions up to 0.1 M. However, at higher concentrations large discrepancies were observed. Compared to the earlier work, the strength of the force was lower by two or three orders of magnitude and the range was diminished. Experiments using the atomic force microscope indicated similar force-distance profiles for the interaction between silicon nitride and mica. With this technique concentrations as high as 5 M can be investigated, and owing to the small radius of curvature much higher pressures can be recorded. Results obtained by both methods confirm that the force is strongly attractive at very small surface separations, in agreement with the theoretical predictions based on calculations of ion correlations. Just outside of that interval the interaction is repulsive, and it can be quantitatively explained by taking into account the adsorption of hydrated ions onto the surface (sign reversal of the effective surface charge) and the layering of co- and counterions. At larger surface separations, the behavior indicates a balance between the double layer repulsion and the van der Waals attraction (the presence of a secondary minimum).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Israelachvili, J. N., & Adams, G. E. (1978) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19787400975 · Cited by 1,812
Pashley, R. M. (1981) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(81)90348-9 · Cited by 958
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Force-distance curves by atomic force microscopy
Cappella, B., & Dietler, G. (1999) · Surface Science Reports · doi:10.1016/s0167-5729(99)00003-5 · Cited by 1,694
Nanoscale Forces and Their Uses in Self‐Assembly
Bishop, K. J. M., Wilmer, C. E., Soh, S., & Grzybowski, B. A. (2009) · Small · doi:10.1002/smll.200900358 · Cited by 1,521
Force Spectroscopy of Molecular Systems—Single Molecule Spectroscopy of Polymers and Biomolecules
Janshoff, A., Neitzert, M., Oberdörfer, Y., & Fuchs, H. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20000915)39:18<3212::aid-anie3212>3.0.co;2-x · Cited by 502
Hofmeister effects: interplay of hydration, nonelectrostatic potentials, and ion size
Parsons, D. F., Boström, M., Nostro, P. L., & Ninham, B. W. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c1cp20538b · Cited by 453
Metadata
- Authors
- Kékicheff, P., Marc̆elja, S., Senden, T. J., & Shubin, V. E.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1993-10-15
- Volume
- 99
- Issue
- 8
- Pages
- 6098-6113
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2079384740
- Cited by
- 205
- References
- 2
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Charge reversal seen in electrical double layer interaction of surfaces immersed in 2:1 calcium electrolyte. https://app.cochat.ai/papers/10.1063/1.465906
- The paper
- Kékicheff, P., Marc̆elja, S., Senden, T. J., & Shubin, V. E. (1993). Charge reversal seen in electrical double layer interaction of surfaces immersed in 2:1 calcium electrolyte. The Journal of Chemical Physics. https://doi.org/10.1063/1.465906
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.