A high-resolution measurement of the low-temperature emissivity of ball infrared black

Tuttle, J., Canavan, Edgar R., DiPirro, Michael, Li, Xiaoyi, Franck, Randy, Green, Daniel·2012·AIP Conference Proceedings

Abstract

High-emissivity coatings are commonly used on thermal control system components. The total hemispheric emissivity values of their surfaces are typically high (nearly 1) at temperatures above about 100 Kelvin, but they drop off steeply at lower temperatures. A precise knowledge of this temperature-dependence is critical to designing passively-cooled components with low operating temperatures. Notable examples are the coatings on thermal radiators used to cool space-flight instruments to temperatures below 40 Kelvin. Past low-temperature paint emissivity measurements have been challenging, often requiring large thermal chambers and typically producing data with high uncertainties below about 100 Kelvin. We describe a relatively inexpensive method of performing high-resolution emissivity measurements in a small cryostat. Results are presented for Ball InfraRed BlackTM (BIRBTM), a proprietary surface coating produced by Ball Aerospace and Technologies Corp (BATC), which is used in space-flight applications.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.4707079

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Space probes frequently employ high-emissivity coatings to maintain instruments within optimal temperature ranges.

    “Specifically, space probes frequently employ high-emissivity coatings to maintain instruments within optimal temperature ranges [14][15][16]”
  • Tuttle et al. found that thinner, lighter BIRB coatings exhibited comparable or even superior emissivity relative to higher-density versions.

    “Furthermore, the team investigated BIRB coatings with varying areal densities and found that thinner, lighter coatings exhibited comparable or even superior emissivity relative to higher-density versions.”
  • The field has seen a gradual shift from liquid-cryogen baths to refrigeration-based cooling systems for cryogenic emissivity measurements.

    “With respect to cooling techniques, the field has seen a gradual shift from liquid-cryogen baths [13,33,36,42,45,46,53] to refrigeration-based cooling systems [16,43,47,51,52].”

Citations

Cited by

Sorted by citations

Metadata

Authors
Tuttle, J., Canavan, E. R., DiPirro, M., Li, X., Franck, R., & Green, D.
Venue
AIP Conference Proceedings
Publisher
AIP
Published
2012
Pages
1505-1512
ISSN
0094-243X
Cited by
5
References
0

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review