Efficiency determination of an electrostatic lunar dust collector by discrete element method
Open accessAbstract
Lunar grains become charged by the sun’s radiation in the tenuous atmosphere of the moon. This leads to lunar dust levitation and particle deposition which often create serious problems in the costly system deployed in lunar exploration. In this study, an electrostatic lunar dust collector (ELDC) is proposed to address the issue and the discrete element method (DEM) is used to investigate the effects of electrical particle-particle interactions, non-uniformity of the electrostatic field, and characteristics of the ELDC. The simulations on 20-μm-sized lunar particles reveal the electrical particle-particle interactions of the dust particles within the ELDC plates require 29% higher electrostatic field strength than that without the interactions for 100% collection efficiency. For the given ELDC geometry, consideration of non-uniformity of the electrostatic field along with electrical interactions between particles on the same ELDC geometry leads to a higher requirement of ∼3.5 kV/m to ensure 100% particle collection. Notably, such an electrostatic field is about 103 times less than required for electrodynamic self-cleaning methods. Finally, it is shown for a “half-size” system that the DEM model predicts greater collection efficiency than the Eulerian-based model at all voltages less than required for 100% efficiency. Halving the ELDC dimensions boosts the particle concentration inside the ELDC, as well as the resulting field strength for a given voltage. Though a lunar photov…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Electrical particle-particle interactions, which increase when particle concentration increases, tend to make ELDC collection efficiency closer to 50%.
“This confirms the results from our previous studies concluding that electrical particle-particle interactions, which increases when particle concentration increases, tend to make ELDC collection efficiency closer to 50% (Afshar-Mohajer et al., 2012).”
From Influence of Back Electrostatic Field on the Collection Efficiency of an Electrostatic Lunar Dust Collector (2014) · cites this paper as Afshar-Mohajer et al., 2012
Assuming 10 × 10 cm plates with a 5 cm distance, 200 pairs of ELDC plates with 175 V applied voltage between each pair are needed to cover 1 m2 of solar panel surface and to provide the previously obtained 3.5 kV/m electric field which runs a clean ELDC with 100% collection efficiency.
“Assuming 10 × 10 cm plates with a 5 cm distance in between, 200 pairs of ELDC plates with 175 V applied voltage between each pair of the plates are needed to cover 1 m 2 of the solar panel surface and to provide the previously obtained 3.5 kV/m electric field which runs a clean ELDC with 100% collection efficiency (Afshar-Mohajer et al., 2012).”
From Influence of Back Electrostatic Field on the Collection Efficiency of an Electrostatic Lunar Dust Collector (2014) · cites this paper as Afshar-Mohajer et al., 2012
Cited by
Sorted by citations
Extra-terrestrial construction processes – Advancements, opportunities and challenges
Lim, S., Prabhu, V. L., Anand, M., & Taylor, L. A. (2017) · Advances in Space Research · doi:10.1016/j.asr.2017.06.038 · Cited by 134 · see citing works
Review of dust transport and mitigation technologies in lunar and Martian atmospheres
Afshar-Mohajer, N., Wu, C.-Y., Curtis, J. S., & Gaier, J. R. (2015) · Advances in Space Research · doi:10.1016/j.asr.2015.06.007 · Cited by 96 · see citing works
Self-citationElectrostatic collection of tribocharged lunar dust simulants
Afshar-Mohajer, N., Wu, C.-Y., & Sorloaica-Hickman, N. (2014) · Advanced Powder Technology · doi:10.1016/j.apt.2014.07.010 · Cited by 14 · see citing works
Self-citationAfshar-Mohajer, N., Thakker, Y., Wu, C.-Y., & Sorloaica-Hickman, N. (2014) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2013.12.0353 · Cited by 8 · see citing works
“5 kV/m electric field which runs a clean ELDC with 100% collection efficiency (Afshar-Mohajer et al., 2012).”
InfluentialSelf-citation
- Authors
- Afshar-Mohajer, N., Wu, C.-Y., & Sorloaica-Hickman, N.
- Affiliations
- University of Florida 1 Department of Environmental Engineering Sciences, , Gainesville, Florida 32611, USA
- University of Central Florida (US)
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2012-07-15
- Volume
- 112
- Issue
- 2
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2020233892
- Cited by
- 22
- References
- 0
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 2 · 2019: 3 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 1
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- Locations
- Journal of Applied Physics (publishedVersion)
- Journal of International Crisis and Risk Communication Research (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Dust and Plasma Wave Phenomena
- Physical Sciences › Engineering › Ocean Engineering › Particle Dynamics in Fluid Flows
- Keywords
- lunar dust, charged dust particles, dust collection efficiency, lunar exploration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review