CoChat

A Josephson junction defect spectrometer for measuring two-level systems

Open access
Stoutimore, M. J. A., Khalil, M. S., Lobb, C. J., Osborn, K. D. · 2012 · Applied Physics Letters
Cited by 26

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We have fabricated and measured Josephson junction (JJ) defect spectrometers, which are frequency-tunable, nearly harmonic oscillators that probe strongly coupled two-level systems (TLSs) in the barrier of a JJ. The JJDSs accommodate a wide range of junction inductances, LJ, while maintaining a resonance frequency, fres, in the range of 4–8 GHz. By applying a magnetic flux bias to tune fres, we detect strongly coupled TLSs in the junction barrier as splittings in the device spectrum. JJDSs fabricated with a via-style Al/thermal AlOx/Al junction and measured between 30–45 mK with single-photon excitation levels show a density of TLSs in the range σTLSh≈0.4-0.5/GHzμm2, and a junction loss tangent of tanδJ≈2.9×10−3.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.4744901

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 26

Metadata

Authors
Stoutimore, M. J. A., Khalil, M. S., Lobb, C. J., & Osborn, K. D.
Venue
Applied Physics Letters
Published
2012-08-06
Volume
101
Issue
6
Pages
062602
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W1977518449
Cited by
26
References
1
FWCI
1.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Josephson junction defect spectrometer for measuring two-level systems. https://app.cochat.ai/papers/10.1063/1.4744901
The paper
Stoutimore, M. J. A., Khalil, M. S., Lobb, C. J., & Osborn, K. D. (2012). A Josephson junction defect spectrometer for measuring two-level systems. Applied Physics Letters. https://doi.org/10.1063/1.4744901

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.