The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultrafast electron diffraction with radio-frequency compressed electron pulses
Abstract
We report on the complete characterization of time resolution in an ultrafast electron diffraction (UED) instrument based on radio-frequency electron pulse compression. The temporal impulse response function of the instrument was determined directly in pump-probe geometry by performing electron-laser pulse cross-correlation measurements using the ponderomotive interaction. With optimal settings, a stable impulse response of 334±10 fs was measured at a bunch charge of 0.1 pC (6.24 × 105 electrons/pulse); a dramatic improvement compared to performance without pulse compression. Phase stability currently limits the impulse response of the UED diffractometer to the range of 334–500 fs, for bunch charges ranging between 0.1 and 0.6 pC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Cited by
A photoinduced metal-like phase of monoclinic VO 2 revealed by ultrafast electron diffraction
Morrison, V. R., Chatelain, R. P., Tiwari, K. L., Hendaoui, A., Bruhács, A., Chaker, M., & Siwick, B. J. (2014) · Science · doi:10.1126/science.1253779 · Cited by 604
Self-citationFeist, A., Bach, N., Rubiano da Silva, N., Danz, T., Möller, M., Priebe, K. E., Domröse, T., Gatzmann, J. G., Rost, S., Schauss, J., et al. (2017) · Ultramicroscopy · doi:10.1016/j.ultramic.2016.12.005 · Cited by 425
Mega-electron-volt ultrafast electron diffraction at SLAC National Accelerator Laboratory
Weathersby, S. P., Brown, G., Centurion, M., Chase, T. F., Coffee, R., Corbett, J., Eichner, J. P., Frisch, J. C., Fry, A. R., Gühr, M., et al. (2015) · Review of Scientific Instruments · doi:10.1063/1.4926994 · Cited by 424
Priebe, K. E., Rathje, C., Yalunin, S. V., Hohage, T., Feist, A., Schäfer, S., & Ropers, C. (2017) · Nature Photonics · doi:10.1038/s41566-017-0045-8 · Cited by 351
Mapping molecular motions leading to charge delocalization with ultrabright electrons
Gao, M., Lu, C., Jean-Ruel, H., Liu, L. C., Marx, A., Onda, K., Koshihara, S.-Y., Nakano, Y., Shao, X., Hiramatsu, T., et al. (2013) · Nature · doi:10.1038/nature12044 · Cited by 286
Metadata
- Authors
- Chatelain, R. P., Morrison, V. R., Godbout, C., & Siwick, B. J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2012-08-20
- Volume
- 101
- Issue
- 8
- Pages
- 081901
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2085751702
- Cited by
- 165
- References
- 1
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrafast electron diffraction with radio-frequency compressed electron pulses. https://app.cochat.ai/papers/10.1063/1.4747155
- The paper
- Chatelain, R. P., Morrison, V. R., Godbout, C., & Siwick, B. J. (2012). Ultrafast electron diffraction with radio-frequency compressed electron pulses. Applied Physics Letters. https://doi.org/10.1063/1.4747155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.