The DOI matches its Crossref record.
A von Hamos x-ray spectrometer based on a segmented-type diffraction crystal for single-shot x-ray emission spectroscopy and time-resolved resonant inelastic x-ray scattering studies
Open accessAbstract
We report on the design and performance of a wavelength-dispersive type spectrometer based on the von Hamos geometry. The spectrometer is equipped with a segmented-type crystal for x-ray diffraction and provides an energy resolution in the order of 0.25 eV and 1 eV over an energy range of 8000 eV–9600 eV. The use of a segmented crystal results in a simple and straightforward crystal preparation that allows to preserve the spectrometer resolution and spectrometer efficiency. Application of the spectrometer for time-resolved resonant inelastic x-ray scattering and single-shot x-ray emission spectroscopy is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bordiga, S., Groppo, E., Agostini, G., van Bokhoven, J. A., & Lamberti, C. (2013) · Chemical Reviews · doi:10.1021/cr2000898 · Cited by 643
Self-citationSwissFEL: The Swiss X-ray Free Electron Laser
Milne, C., Schietinger, T., Aiba, M., Alarcon, A., Alex, J., Anghel, A., Arsov, V., Beard, C., Beaud, P., Bettoni, S., et al. (2017) · Applied Sciences · doi:10.3390/app7070720 · Cited by 349
Self-citationThe Comparison between Single Atom Catalysis and Surface Organometallic Catalysis
Samantaray, M. K., D’Elia, V., Pump, E., Falivene, L., Harb, M., Ould Chikh, S., Cavallo, L., & Basset, J.-M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00238 · Cited by 287
Photoinduced Structural Dynamics of Molecular Systems Mapped by Time-Resolved X-ray Methods
Chergui, M., & Collet, E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00831 · Cited by 261
Saveleva, V. A., Ebner, K., Ni, L., Smolentsev, G., Klose, D., Zitolo, A., Marelli, E., Li, J., Medarde, M., Safonova, O. V., et al. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202016951 · Cited by 82
Self-citation
Metadata
- Authors
- Szlachetko, J., Nachtegaal, M., de Boni, E., Willimann, M., Safonova, O., Sa, J., Smolentsev, G., Szlachetko, M., van Bokhoven, J. A., Dousse, J.-C., Hoszowska, J., Kayser, Y., Jagodzinski, P., Bergamaschi, A., Schmitt, B., David, C., & Lücke, A.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2012-10-01
- Volume
- 83
- Issue
- 10
- Pages
- 103105-103105
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2065608038
- Cited by
- 180
- References
- 0
- FWCI
- 15.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A von Hamos x-ray spectrometer based on a segmented-type diffraction crystal for single-shot x-ray emission spectroscopy and time-resolved resonant inelastic x-ray scattering studies. https://app.cochat.ai/papers/10.1063/1.4756691
- The paper
- Szlachetko, J., Nachtegaal, M., de Boni, E., Willimann, M., Safonova, O., Sa, J., Smolentsev, G., Szlachetko, M., van Bokhoven, J. A., Dousse, J.-C., Hoszowska, J., Kayser, Y., Jagodzinski, P., Bergamaschi, A., Schmitt, B., David, C., & Lücke, A. (2012). A von Hamos x-ray spectrometer based on a segmented-type diffraction crystal for single-shot x-ray emission spectroscopy and time-resolved resonant inelastic x-ray scattering studies. Review of Scientific Instruments. https://doi.org/10.1063/1.4756691
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.