12% magnetic field-induced strain in Ni-Mn-Ga-based non-modulated martensite
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Magnetic field-induced strain (MFIS) of 12% is reported in ferromagnetic Ni46Mn24Ga22Co4Cu4 martensite exhibiting non-modulated (NM) tetragonal crystal structure with lattice parameter ratio c/a>1. The strain was measured at ambient temperature in a magnetic field of the order of 1 T. The twinning stress σTW and the magnetic stress σMAG were also measured and the condition for a giant MFIS observation σTW<σMAG was confirmed. The MFIS was achieved in NM Ni46Mn24Ga22Co4Cu4 martensite by considerable lowering of the σTW value as compared to the values for NM martensites in ternary Ni-Mn-Ga system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Magnetic Materials
(2009) · Handbook of Magnetic Materials · doi:10.1016/s1567-2719(09)01808-3 · Cited by 1,638
Magnetic shape-memory effects in a crystal
Лавров, А. Н., Komiya, S., & Ando, Y. (2002) · Nature · doi:10.1038/418385a · Cited by 117
Cited by
Metadata
- Authors
- Sozinov, A., Lanska, N., Soroka, A., & Zou, W.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2013-01-14
- Volume
- 102
- Issue
- 2
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2016194521
- Cited by
- 435
- References
- 2
- FWCI
- 16.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 12% magnetic field-induced strain in Ni-Mn-Ga-based non-modulated martensite. https://app.cochat.ai/papers/10.1063/1.4775677
- The paper
- Sozinov, A., Lanska, N., Soroka, A., & Zou, W. (2013). 12% magnetic field-induced strain in Ni-Mn-Ga-based non-modulated martensite. Applied Physics Letters. https://doi.org/10.1063/1.4775677
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.