Cited by 102Terahertz technology and applicationsLaser-Matter Interactions and ApplicationsSpectroscopy and Quantum Chemical Studies

Theory for determination of the low-frequency time-dependent response function in liquids using time-resolved terahertz pulse spectroscopy

Kindt, James T., Schmuttenmaer, Charles A.·1999·The Journal of Chemical Physics

Abstract

With the current rapid improvement in techniques for generating and detecting femtosecond terahertz (fs-THz) pulses, it is now possible to detect time-dependent perturbations to low-frequency intermolecular far-infrared modes during solvation events. The interpretation of these time-resolved terahertz spectroscopy experiments has generally relied on a collapse of the information available in the fs-THz pulse to give a one-dimensional time-dependent function, whose physical significance is not well defined. We describe a method to exploit the full electric field profile of the pulse as a function of pump/probe delay time to obtain a two-dimensional function that describes the system’s time-dependent dielectric response. We discuss the physical significance of this response function in terms of the time evolution of solute/solvent modes following photoexcitation, and give examples to show how its qualitative features relate to the measurable signal.

Integrity signals

Registry

Crossref · 10.1063/1.478766

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The straightforward interpretation of THz-TDS as a snapshot of the optical conductivity spectrum breaks down when characteristic relaxation times are comparable to the photoexcitation delay, because the Fourier transform involves times that precede photoexcitation.

    “However, the straightforward interpretation of THz-TDS as a snapshot of the optical conductivity spectrum breaks down when the characteristic relaxation times are comparable to the photoexcitation delay, because the Fourier transform involves times that precede photoexcitation. 1,9-16”

Cited by

Sorted by citations

Authors
Kindt, J. T., & Schmuttenmaer, C. A.
Affiliations
Yale University (US)
Venue
The Journal of Chemical Physics
Published
1999-05-01
Volume
110
Issue
17
Pages
8589-8596
ISSN
  • 0021-9606 (ISSN-L)
  • 1089-7690
OpenAlex
W2091809372
Cited by
102
References
0
Citations by year
2026: 2 · 2025: 4 · 2024: 2 · 2023: 6 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 3 · 2017: 6 · 2016: 2 · 2015: 4 · 2014: 5 · 2013: 1 · 2012: 4
FWCI
5.33
Type
journal article
Language
en
Open access
closed
Locations
The Journal of Chemical Physics (publishedVersion)
Funders
  • National Science Foundation
  • Division of Chemistry
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
Keywords
time-resolved terahertz spectroscopy, solvation dynamics, photoexcitation, liquids

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review