CoChat

Experimental distinction between phase shifts and time delays: Implications for femtosecond spectroscopy and coherent control of chemical reactions

Albrecht, Allison W., Hybl, John D., Gallagher Faeder, Sarah M., Jonas, David M. · 1999 · The Journal of Chemical Physics
Cited by 133

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Two different definitions of phase shifts and time delays are contrasted and shown to match different experimental methods of generating delayed pulses. Phase shifts and time delays are usually defined in terms of a carrier wave in magnetic resonance, but definitions based on the envelope of a single pulse are useful in optics. It is demonstrated experimentally that a frequency domain measurement using spectral interferometry can simultaneously measure phase shifts with an accuracy of 0.1 rad (2σ) and time delays with a precision of 40 attoseconds (2σ) for 25 femtosecond optical pulses. Envelope time delays are generated by pathlength differences in an interferometer. Constant spectral phase shifts are demonstrated by diffracting pulses from a variable phase volume diffraction grating. Experimental requirements for phase-resolved spectroscopy are outlined. The theory of phase-locked pulse pair techniques is reexamined, and it is concluded that linear experiments with phase-locked pulse pairs are completely equivalent to Fourier transform absorption spectroscopy and do not measure the refractive index or real part of the susceptibility. It is shown that Fourier sine and cosine transformations of truncated time domain signals which do not match the symmetry of the complete signal can produce a false dispersive susceptibility because they are equivalent to Kramers–Kronig inversion of finite bandwidth absorption data. A procedure for shifting π/2 phase-locked transients by a quarter cycle of delay to generate a transient with a π/2 spectral phase shift is given. Equations used to calculate femtosecond nonlinear optical signals have assumed carrier wave delays. Modifications to these equations are required when envelope delays are generated by interferometer pathlength differences and modified equations are given. The modified equations yield significantly different results for phase-resolved or interferometric experiments. In particular, the modified equations are needed to calculate indirectly (interferometrically) detected frequencies and the real and imaginary parts of two-dimensional Fourier transform spectra. The role of the refractive index and real part of the frequency domain susceptibility in nonlinear experiments with phase-locked pulse pairs is explored. It is concluded that experiments such as the heterodyne detected stimulated photon echo are insensitive to nonlinear refractive index changes under some circumstances. Finally, modifications of some equations used in the theory of coherent control are needed to match theory with experimental practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.480457

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Albrecht, A. W., Hybl, J. D., Gallagher Faeder, S. M., & Jonas, D. M.
Venue
The Journal of Chemical Physics
Published
1999-12-22
Volume
111
Issue
24
Pages
10934-10956
ISSN
  • 0021-9606 (ISSN-L)
  • 1089-7690
OpenAlex
W1987925214
Cited by
133
References
2
FWCI
4.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.