Experimental distinction between phase shifts and time delays: Implications for femtosecond spectroscopy and coherent control of chemical reactions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Two different definitions of phase shifts and time delays are contrasted and shown to match different experimental methods of generating delayed pulses. Phase shifts and time delays are usually defined in terms of a carrier wave in magnetic resonance, but definitions based on the envelope of a single pulse are useful in optics. It is demonstrated experimentally that a frequency domain measurement using spectral interferometry can simultaneously measure phase shifts with an accuracy of 0.1 rad (2σ) and time delays with a precision of 40 attoseconds (2σ) for 25 femtosecond optical pulses. Envelope time delays are generated by pathlength differences in an interferometer. Constant spectral phase shifts are demonstrated by diffracting pulses from a variable phase volume diffraction grating. Experimental requirements for phase-resolved spectroscopy are outlined. The theory of phase-locked pulse pair techniques is reexamined, and it is concluded that linear experiments with phase-locked pulse pairs are completely equivalent to Fourier transform absorption spectroscopy and do not measure the refractive index or real part of the susceptibility. It is shown that Fourier sine and cosine transformations of truncated time domain signals which do not match the symmetry of the complete signal can produce a false dispersive susceptibility because they are equivalent to Kramers–Kronig inversion of finite bandwidth absorption data. A procedure for shifting π/2 phase-locked transients by a quarter cycle of delay to generate a transient with a π/2 spectral phase shift is given. Equations used to calculate femtosecond nonlinear optical signals have assumed carrier wave delays. Modifications to these equations are required when envelope delays are generated by interferometer pathlength differences and modified equations are given. The modified equations yield significantly different results for phase-resolved or interferometric experiments. In particular, the modified equations are needed to calculate indirectly (interferometrically) detected frequencies and the real and imaginary parts of two-dimensional Fourier transform spectra. The role of the refractive index and real part of the frequency domain susceptibility in nonlinear experiments with phase-locked pulse pairs is explored. It is concluded that experiments such as the heterodyne detected stimulated photon echo are insensitive to nonlinear refractive index changes under some circumstances. Finally, modifications of some equations used in the theory of coherent control are needed to match theory with experimental practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Magnetic Resonance
Slichter, C. P. (1990) · Springer Series in Solid-State Sciences · doi:10.1007/978-3-662-09441-9 · Cited by 5,520
Coherent Control of Quantum Dynamics: The Dream Is Alive
Warren, W. S., Rabitz, H., & Dahleh, M. (1993) · Science · doi:10.1126/science.259.5101.1581 · Cited by 1,058
Cited by
Two-Dimensional Femtosecond Spectroscopy
Jonas, D. M. (2003) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.54.011002.103907 · Cited by 1,198
Self-citationAbramavicius, D., Palmieri, B., Voronine, D. V., Šanda, F., & Mukamel, S. (2009) · Chemical Reviews · doi:10.1021/cr800268n · Cited by 528
Phase-stabilized two-dimensional electronic spectroscopy
Brixner, T., Mančal, T., Stiopkin, I. V., & Fleming, G. R. (2004) · The Journal of Chemical Physics · doi:10.1063/1.1776112 · Cited by 523
Shim, S.-H., & Zanni, M. T. (2009) · Phys. Chem. Chem. Phys. · doi:10.1039/b813817f · Cited by 425
Two-dimensional Fourier transform electronic spectroscopy
Hybl, J. D., Albrecht Ferro, A., & Jonas, D. M. (2001) · The Journal of Chemical Physics · doi:10.1063/1.1398579 · Cited by 405
Self-citationSpectral resolution and sampling issues in Fourier-transform spectral interferometry
Dorrer, C., Belabas, N., Likforman, J.-P., & Joffre, M. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001795 · Cited by 364
Fecko, C. J., Loparo, J. J., Roberts, S. T., & Tokmakoff, A. (2005) · The Journal of Chemical Physics · doi:10.1063/1.1839179 · Cited by 322
Room-temperature ultrafast nonlinear spectroscopy of a single molecule
Liebel, M., Toninelli, C., & van Hulst, N. F. (2018) · Nature Photonics · doi:10.1038/s41566-017-0056-5 · Cited by 84
Carrier envelope phase shifter for broadband terahertz pulses
Kawada, Y., Yasuda, T., & Takahashi, H. (2016) · Optics Letters · doi:10.1364/ol.41.000986 · Cited by 30
Metadata
- Authors
- Albrecht, A. W., Hybl, J. D., Gallagher Faeder, S. M., & Jonas, D. M.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1999-12-22
- Volume
- 111
- Issue
- 24
- Pages
- 10934-10956
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W1987925214
- Cited by
- 133
- References
- 2
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.