The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Inverse spin Hall effect in nanometer-thick yttrium iron garnet/Pt system
Open accessAbstract
High quality nanometer-thick (20 nm, 7 nm, and 4 nm) epitaxial Yttrium Iron Garnet (YIG) films have been grown on gadolinium gallium garnet substrates using pulsed laser deposition. The Gilbert damping coefficient for the 20 nm thick films is 2.3 × 10−4 which is the lowest value reported for sub-micrometric thick films. We demonstrate Inverse spin Hall effect (ISHE) detection of propagating spin waves using Pt. The amplitude and the lineshape of the ISHE voltage correlate well to the increase of the Gilbert damping when decreasing thickness of YIG. Spin Hall effect based loss-compensation experiments have been conducted but no change in the magnetization dynamics could be detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hirsch, J. E. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.1834 · Cited by 3,163
Conversion of spin current into charge current at room temperature: Inverse spin-Hall effect
Saitoh, E., Ueda, M., Miyajima, H., & Tatara, G. (2006) · Applied Physics Letters · doi:10.1063/1.2199473 · Cited by 2,157
Transmission of electrical signals by spin-wave interconversion in a magnetic insulator
Kajiwara, Y., Harii, K., Takahashi, S., Ohe, J., Uchida, K., Mizuguchi, M., Umezawa, H., Kawai, H., Ando, K., Takanashi, K., et al. (2010) · Nature · doi:10.1038/nature08876 · Cited by 1,642
Spin transfer torque devices utilizing the giant spin Hall effect of tungsten
Pai, C.-F., Liu, L., Li, Y., Tseng, H. W., Ralph, D. C., & Buhrman, R. A. (2012) · Applied Physics Letters · doi:10.1063/1.4753947 · Cited by 1,407
Electric Manipulation of Spin Relaxation Using the Spin Hall Effect
Ando, K., Takahashi, S., Harii, K., Sasage, K., Ieda, J., Maekawa, S., & Saitoh, E. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.036601 · Cited by 680
Magnetic nano-oscillator driven by pure spin current
Demidov, V. E., Urazhdin, S., Ulrichs, H., Tiberkevich, V., Slavin, A., Baither, D., Schmitz, G., & Demokritov, S. O. (2012) · Nature Materials · doi:10.1038/nmat3459 · Cited by 665
Comparative measurements of inverse spin Hall effects and magnetoresistance in YIG/Pt and YIG/Ta
Hahn, C., de Loubens, G., Klein, O., Viret, M., Naletov, V. V., & Ben Youssef, J. (2013) · Physical Review B · doi:10.1103/physrevb.87.174417 · Cited by 541
Self-citationAlthammer, M., Meyer, S., Nakayama, H., Schreier, M., Altmannshofer, S., Weiler, M., Huebl, H., Geprägs, S., Opel, M., Gross, R., et al. (2013) · Physical Review B · doi:10.1103/physrevb.87.224401 · Cited by 536
Spin Pumping at the Magnetic Insulator (YIG)/Normal Metal (Au) Interfaces
Heinrich, B., Burrowes, C., Montoya, E., Kardasz, B., Girt, E., Song, Y.-Y., Sun, Y., & Wu, M. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.066604 · Cited by 445
Niimi, Y., Kawanishi, Y., Wei, D. H., Deranlot, C., Yang, H. X., Chshiev, M., Valet, T., Fert, A., & Otani, Y. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.156602 · Cited by 326
Self-citation
Cited by
Chumak, A. V., Vasyuchka, V. I., Serga, A. A., & Hillebrands, B. (2015) · Nature Physics · doi:10.1038/nphys3347 · Cited by 2,591
Rojas-Sánchez, J.-C., Reyren, N., Laczkowski, P., Savero, W., Attané, J.-P., Deranlot, C., Jamet, M., George, J.-M., Vila, L., & Jaffrès, H. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.106602 · Cited by 674
Self-citationReview and prospects of magnonic crystals and devices with reprogrammable band structure
Krawczyk, M., & Grundler, D. (2014) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/26/12/123202 · Cited by 619
Generation of coherent spin-wave modes in yttrium iron garnet microdiscs by spin–orbit torque
Collet, M., de Milly, X., d’Allivy Kelly, O., Naletov, V. V., Bernard, R., Bortolotti, P., Ben Youssef, J., Demidov, V. E., Demokritov, S. O., Prieto, J. L., et al. (2016) · Nature Communications · doi:10.1038/ncomms10377 · Cited by 259
Self-citation
Metadata
- Authors
- d'Allivy Kelly, O., Anane, A., Bernard, R., Ben Youssef, J., Hahn, C., Molpeceres, A. H., Carrétéro, C., Jacquet, E., Deranlot, C., Bortolotti, P., Lebourgeois, R., Mage, J.-C., de Loubens, G., Klein, O., Cros, V., & Fert, A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2013-08-19
- Volume
- 103
- Issue
- 8
- Pages
- 082408
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1546110754
- Cited by
- 252
- References
- 17
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inverse spin Hall effect in nanometer-thick yttrium iron garnet/Pt system. https://app.cochat.ai/papers/10.1063/1.4819157
- The paper
- d'Allivy Kelly, O., Anane, A., Bernard, R., Ben Youssef, J., Hahn, C., Molpeceres, A. H., Carrétéro, C., Jacquet, E., Deranlot, C., Bortolotti, P., Lebourgeois, R., Mage, J.-C., de Loubens, G., Klein, O., Cros, V., & Fert, A. (2013). Inverse spin Hall effect in nanometer-thick yttrium iron garnet/Pt system. Applied Physics Letters. https://doi.org/10.1063/1.4819157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.