The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments
Open accessAbstract
This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 1014 photon/mm2. The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 μm square pixels while keeping the single photon detection capability for X-ray photons higher than 6 keV and a readout speed of 60 frames/s. The system development also included a detector system for the MPCCD sensor. This paper summarizes the performance, calibration methods, and operation status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
First lasing and operation of an ångstrom-wavelength free-electron laser
Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F.-J., et al. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.176 · Cited by 3,167
The European Photon Imaging Camera on XMM-Newton: The pn-CCD camera
Strüder, L., Briel, U., Dennerl, K., Hartmann, R., Kendziorra, E., Meidinger, N., Pfeffermann, E., Reppin, C., Aschenbach, B., Bornemann, W., et al. (2001) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20000066 · Cited by 2,936
Self-citationThe European Photon Imaging Camera on XMM-Newton: The MOS cameras
Turner, M. J. L., Abbey, A., Arnaud, M., Balasini, M., Barbera, M., Belsole, E., Bennie, P. J., Bernard, J. P., Bignami, G. F., Boer, M., et al. (2001) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20000087 · Cited by 2,351
Self-citationA compact X-ray free-electron laser emitting in the sub-ångström region
Ishikawa, T., Aoyagi, H., Asaka, T., Asano, Y., Azumi, N., Bizen, T., Ego, H., Fukami, K., Fukui, T., Furukawa, Y., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.141 · Cited by 1,819
Self-citationAtomic form factors, incoherent scattering functions, and photon scattering cross sections
Hubbell, J. H., Veigele, W. J., Briggs, E. A., Brown, R. T., Cromer, D. T., & Howerton, R. J. (1975) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555523 · Cited by 1,792
X-Ray Imaging Spectrometer (XIS) on Board Suzaku
Koyama, K., Tsunemi, H., Dotani, T., Bautz, M. W., Hayashida, K., Tsuru, T. G., Matsumoto, H., Ogawara, Y., Ricker, G. R., Doty, J., et al. (2007) · Publications of the Astronomical Society of Japan · doi:10.1093/pasj/59.sp1.s23 · Cited by 1,044
A unified mobility model for device simulation—I. Model equations and concentration dependence
Klaassen, D. B. M. (1992) · Solid-State Electronics · doi:10.1016/0038-1101(92)90325-7 · Cited by 917
Kuo, C., Chen, C.-H., & Huang, M. H. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200700356 · Cited by 383
Strüder, L., Epp, S., Rolles, D., Hartmann, R., Holl, P., Lutz, G., Soltau, H., Eckart, R., Reich, C., Heinzinger, K., et al. (2010) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2009.12.053 · Cited by 306
Tono, K., Togashi, T., Inubushi, Y., Sato, T., Katayama, T., Ogawa, K., Ohashi, H., Kimura, H., Takahashi, S., Takeshita, K., et al. (2013) · New Journal of Physics · doi:10.1088/1367-2630/15/8/083035 · Cited by 273
Self-citation
Cited by
Atomic inner-shell laser at 1.5-ångström wavelength pumped by an X-ray free-electron laser
Yoneda, H., Inubushi, Y., Nagamine, K., Michine, Y., Ohashi, H., Yumoto, H., Yamauchi, K., Mimura, H., Kitamura, H., Katayama, T., et al. (2015) · Nature · doi:10.1038/nature14894 · Cited by 175
Self-citation
Metadata
- Authors
- Kameshima, T., Ono, S., Kudo, T., Ozaki, K., Kirihara, Y., Kobayashi, K., Inubushi, Y., Yabashi, M., Horigome, T., Holland, A., Holland, K., Burt, D., Murao, H., & Hatsui, T.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2014-03-01
- Volume
- 85
- Issue
- 3
- Pages
- 033110-033110
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2105000521
- Cited by
- 262
- References
- 21
- FWCI
- 12.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments. https://app.cochat.ai/papers/10.1063/1.4867668
- The paper
- Kameshima, T., Ono, S., Kudo, T., Ozaki, K., Kirihara, Y., Kobayashi, K., Inubushi, Y., Yabashi, M., Horigome, T., Holland, A., Holland, K., Burt, D., Murao, H., & Hatsui, T. (2014). Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments. Review of Scientific Instruments. https://doi.org/10.1063/1.4867668
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.