A microfluidic device to study cancer metastasis under chronic and intermittent hypoxia
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Metastatic cancer cells must traverse a microenvironment ranging from extremely hypoxic, within the tumor, to highly oxygenated, within the host's vasculature. Tumor hypoxia can be further characterized by regions of both chronic and intermittent hypoxia. We present the design and characterization of a microfluidic device that can simultaneously mimic the oxygenation conditions observed within the tumor and model the cell migration and intravasation processes. This device can generate spatial oxygen gradients of chronic hypoxia and produce dynamically changing hypoxic microenvironments in long-term culture of cancer cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hidalgo, M. (2010) · New England Journal of Medicine · doi:10.1056/nejmra0901557 · Cited by 2,570
A microfluidic 3D in vitro model for specificity of breast cancer metastasis to bone
Bersini, S., Jeon, J. S., Dubini, G., Arrigoni, C., Chung, S., Charest, J. L., Moretti, M., & Kamm, R. D. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.050 · Cited by 534
Tumor hypoxia and malignant progression
Vaupel, P., Mayer, A., & Höckel, M. (2004) · Methods in Enzymology · doi:10.1016/s0076-6879(04)81023-1 · Cited by 496
Engineering microscale cellular niches for three-dimensional multicellular co-cultures
Huang, C. P., Lu, J., Seon, H., Lee, A. P., Flanagan, L. A., Kim, H.-Y., Putnam, A. J., & Jeon, N. L. (2009) · Lab on a Chip · doi:10.1039/b818401a · Cited by 384
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Almendros, I., Wang, Y., Becker, L., Lennon, F. E., Zheng, J., Coats, B. R., Schoenfelt, K. S., Carreras, A., Hakim, F., Zhang, S. X., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201310-1830oc · Cited by 201
Malec, V., Gottschald, O. R., Li, S., Rose, F., Seeger, W., & Hänze, J. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2010.03.008 · Cited by 149
Abaci, H. E., Devendra, R., Smith, Q., Gerecht, S., & Drazer, G. (2012) · Biomedical Microdevices · doi:10.1007/s10544-011-9592-9 · Cited by 67
Cited by
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
A review of microfluidic approaches for investigating cancer extravasation during metastasis
Ma, Y.-H. V., Middleton, K., You, L., & Sun, Y. (2018) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.104 · Cited by 154
Applications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
Metastasis in context: modeling the tumor microenvironment with cancer-on-a-chip approaches
Sleeboom, J. J. F., Eslami Amirabadi, H., Nair, P., Sahlgren, C. M., & den Toonder, J. M. J. (2018) · Disease Models & Mechanisms · doi:10.1242/dmm.033100 · Cited by 122
“Based on this method, a gradient across a 3D hydrogel (Oppegard and Eddington, 2013) and a gradient across a compartmentalized chip with a collagen ECM and a vessel-mimicking channel (Acosta et al., 2014) Funamoto et al., 2012), and thus enabled more accurate quantification of the oxygen response.”
Metadata
- Authors
- Acosta, M. A., Jiang, X., Huang, P.-K., Cutler, K. B., Grant, C. S., Walker, G. M., & Gamcsik, M. P.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2014-09-01
- Volume
- 8
- Issue
- 5
- Pages
- 054117-054117
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W1966346232
- Cited by
- 58
- References
- 8
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfluidic device to study cancer metastasis under chronic and intermittent hypoxia. https://app.cochat.ai/papers/10.1063/1.4898788
- The paper
- Acosta, M. A., Jiang, X., Huang, P.-K., Cutler, K. B., Grant, C. S., Walker, G. M., & Gamcsik, M. P. (2014). A microfluidic device to study cancer metastasis under chronic and intermittent hypoxia. Biomicrofluidics. https://doi.org/10.1063/1.4898788
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.