Reusable bi-directional 3 ω sensor to measure thermal conductivity of 100- μ m thick biological tissues
Abstract
Accurate knowledge of the thermal conductivity (k) of biological tissues is important for cryopreservation, thermal ablation, and cryosurgery. Here, we adapt the 3ω method-widely used for rigid, inorganic solids-as a reusable sensor to measure k of soft biological samples two orders of magnitude thinner than conventional tissue characterization methods. Analytical and numerical studies quantify the error of the commonly used "boundary mismatch approximation" of the bi-directional 3ω geometry, confirm that the generalized slope method is exact in the low-frequency limit, and bound its error for finite frequencies. The bi-directional 3ω measurement device is validated using control experiments to within ±2% (liquid water, standard deviation) and ±5% (ice). Measurements of mouse liver cover a temperature ranging from -69 °C to +33 °C. The liver results are independent of sample thicknesses from 3 mm down to 100 μm and agree with available literature for non-mouse liver to within the measurement scatter.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The bi-directional three-omega technique allows quantification of samples in contact with the sensor.
“Nevertheless, the bi-directional three-omega technique presented in [4] allows the quantification of samples in contact to the sensor.”
From Three-Omega Method for Characterization of Thermal Conductivity of Samples at Cryogenic Temperatures (2025) · cites this paper as [4]
Cites
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928 · see citing works
Thermal Conductance of Hydrophilic and Hydrophobic Interfaces
Ge, Z., Cahill, D. G., & Braun, P. V. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.186101 · Cited by 455 · see citing works
1 ω , 2 ω , and 3ω methods for measurements of thermal properties
Dames, C., & Chen, G. (2005) · Review of Scientific Instruments · doi:10.1063/1.2130718 · Cited by 275 · see citing works
Self-citationAn optical pump-probe technique for measuring the thermal conductivity of liquids
Schmidt, A., Chiesa, M., Chen, X., & Chen, G. (2008) · Review of Scientific Instruments · doi:10.1063/1.2937458 · Cited by 184 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Three-Omega Method for Characterization of Thermal Conductivity of Samples at Cryogenic Temperatures
Rincon-Ruiz, C., Jöhrmann, N., Grosse-Kockert, C., Zschenderlein, U., & Wunderle, B. (2025) · 2025 31st International Workshop on Thermal Investigations of ICs and Systems (THERMINIC) · doi:10.1109/therminic65879.2025.11216875
- Authors
- Lubner, S. D., Choi, J., Wehmeyer, G., Waag, B., Mishra, V., Natesan, H., Bischof, J. C., & Dames, C.
- Affiliations
- University of Minnesota (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2015-01-01
- Volume
- 86
- Issue
- 1
- Pages
- 014905-014905
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2018247694
- Cited by
- 66
- References
- 4
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 4 · 2023: 4 · 2022: 8 · 2021: 6 · 2020: 8 · 2019: 5 · 2018: 5 · 2017: 4 · 2016: 5 · 2015: 1
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of California, Berkeley
- National Science Foundation (1106400, 1236760)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
- Keywords
- 3ω method, thermal conductivity measurement, biological tissue, reusable sensors, mouse liver, cryopreservation, thermal ablation, cryosurgery, low-frequency limit, sample thickness, liquid water, ice
- MeSH terms
- Animals, Computer Simulation, Ice, Liver, Models, Biological, Temperature, Thermal Conductivity, Water, Mice, Electrical Equipment and Supplies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review