The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Elastocaloric effect of Ni-Ti wire for application in a cooling device
Abstract
We report on the elastocaloric effect of a superelastic Ni-Ti wire to be used in a cooling device. Initially, each evaluated wire was subjected to 400 loading/unloading training cycles in order to stabilize its superelastic behavior. The wires were trained at different temperatures, which lead to different stabilized superelastic behaviors. The stabilized (trained) wires were further tested isothermally (at low strain-rate) and adiabatically (at high strain-rate) at different temperatures (from 312 K to 342 K). We studied the impact of the training temperature and resulting superelastic behavior on the adiabatic temperature changes. The largest measured adiabatic temperature change during loading was 25 K with a corresponding 21 K change during unloading (at 322 K). A special focus was put on the irreversibilities in the adiabatic temperature changes between loading and unloading. It was shown that there are two sources of the temperature irreversibilities: the hysteresis (and related entropy generation) and the temporary residual strain immediately after unloading, respectively. The latter results in the temporary bending of the wire and reduced negative adiabatic temperature change. The paper also shows the impact of the applied strain on the adiabatic temperature changes as well as the distribution of the elastocaloric effect over the wire during loading in the case of two wires trained at different temperatures and the virgin wire, respectively. In the end, we propose guidelines about the required material properties for an efficient elastocaloric cooling device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wayman, C. M., & 大塚, 和. (1998) · Cambridge University Press eBooks · Cited by 3,134
Review of progress in shape-memory polymers
Liu, C., Qin, H., & Mather, P. T. (2007) · Journal of Materials Chemistry · doi:10.1039/b615954k · Cited by 1,942
Caloric materials near ferroic phase transitions
Moya, X., Kar-Narayan, S., & Mathur, N. D. (2014) · Nature Materials · doi:10.1038/nmat3951 · Cited by 1,428
Elastocaloric Effect Associated with the Martensitic Transition in Shape-Memory Alloys
Bonnot, E., Romero, R., Mañosa, L., Vives, E., & Planes, A. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.125901 · Cited by 575
Caloric Effects in Ferroic Materials: New Concepts for Cooling
Fähler, S., Rößler, U. K., Kastner, O., Eckert, J., Eggeler, G., Emmerich, H., Entel, P., Müller, S., Quandt, E., & Albe, K. (2012) · Advanced Engineering Materials · doi:10.1002/adem.201100178 · Cited by 348
Large temperature span and giant refrigerant capacity in elastocaloric Cu-Zn-Al shape memory alloys
Mañosa, L., Jarque-Farnos, S., Vives, E., & Planes, A. (2013) · Applied Physics Letters · doi:10.1063/1.4832339 · Cited by 247
Experimental results for a novel rotary active magnetic regenerator
Engelbrecht, K. L., Eriksen, D., Bahl, C. R. H., Bjørk, R., Geyti, J., Lozano, J. A., Nielsen, K. K., Saxild, F., Smith, A., & Pryds, N. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.05.003 · Cited by 155
Self-citationThermodynamics of thermoelastic martensitic transformations
Ortı́n, J., & Planes, A. (1989) · Acta Metallurgica · doi:10.1016/0001-6160(89)90175-2 · Cited by 153
A comprehensive experimental analysis of gadolinium active magnetic regenerators
Tušek, J., Kitanovski, A., Zupan, S., Prebil, I., & Poredoš, A. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.01.015 · Cited by 128
Self-citationElastocaloric modeling of natural rubber
Guyomar, D., Yang, L., Sebald, G., Cottinet, P., Ducharne, B., & Capsal, J. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.03.032 · Cited by 81
Stabilization of the shape memory effect in NiTi: an experimental investigation
Erbstoeszer, B., Armstrong, B. W., Taya, M., & Inoue, K. (2000) · Scripta Materialia · doi:10.1016/s1359-6462(00)00350-x · Cited by 37
Cited by
Shi, J., Han, D., Li, Z., Yang, L., Lu, S.-G., Zhong, Z., Chen, J., Zhang, Q. M., & Qian, X. (2019) · Joule · doi:10.1016/j.joule.2019.03.021 · Cited by 462
Direct and indirect measurements on electrocaloric effect: Recent developments and perspectives
Liu, Y., Scott, J. F., & Dkhil, B. (2016) · Applied Physics Reviews · doi:10.1063/1.4958327 · Cited by 319
Present and future caloric refrigeration and heat-pump technologies
Kitanovski, A., Plaznik, U., Tomc, U., & Poredoš, A. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.06.008 · Cited by 274
Sustainability through alloy design: Challenges and opportunities
Cann, J. L., De Luca, A., Dunand, D. C., Dye, D., Miracle, D. B., Oh, H. S., Olivetti, E. A., Pollock, T. M., Poole, W. J., Yang, R., et al. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100722 · Cited by 191
Metadata
- Authors
- Tušek, J., Engelbrecht, K., Mikkelsen, L. P., & Pryds, N.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2015-03-24
- Volume
- 117
- Issue
- 12
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2038120838
- Cited by
- 289
- References
- 11
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.