The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electroosmosis-modulated peristaltic transport in microfluidic channels
Abstract
We analyze the peristaltic motion of aqueous electrolytes altered by means of applied electric fields. Handling electrolytes in typical peristaltic channel material such as polyvinyl chloride and Teflon leads to the generation of a net surface charge on the channel walls, which attracts counter-ions and repels co-ions from the aqueous solution, thus leading to the formation of an electrical double layer—a region of net charges near the wall. We analyze the spatial distribution of pressure and wall shear stress for a continuous wave train and single pulse peristaltic wave in the presence of an electrical (electroosmotic) body force, which acts on the net charges in the electrical double layer. We then analyze the effect of the electroosmotic body force on the particle reflux as elucidated through the net displacement of neutrally buoyant particles in the flow as the peristaltic waves progress. The impact of combined electroosmosis and peristalsis on trapping of a fluid volume (e.g., bolus) inside the travelling wave is also discussed. The present analysis goes beyond the traditional analysis, which neglects the possibility of coupling the net pumping of fluids due to peristalsis and allows us to derive general expressions for the pressure drop and flow rate in order to set up a general framework for incorporating flow control and actuation by simultaneous peristalsis and application of electric fields to aqueous solutions. It is envisaged that the results presented here may act as a model for the design of lab-on-a-chip devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
Cited by
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
Self-citation
Metadata
- Authors
- Bandopadhyay, A., Tripathi, D., & Chakraborty, S.
- Venue
- Physics of Fluids
- Publisher
- AIP Publishing
- Published
- 2016-05-01
- Volume
- 28
- Issue
- 5
- ISSN
- 1070-6631 (ISSN-L)
- 1089-7666
- OpenAlex
- W2392180684
- Cited by
- 176
- References
- 2
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroosmosis-modulated peristaltic transport in microfluidic channels. https://app.cochat.ai/papers/10.1063/1.4947115
- The paper
- Bandopadhyay, A., Tripathi, D., & Chakraborty, S. (2016). Electroosmosis-modulated peristaltic transport in microfluidic channels. Physics of Fluids. https://doi.org/10.1063/1.4947115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.