The DOI matches its Crossref record.
Fabrication of all diamond scanning probes for nanoscale magnetometry
Open accessAbstract
The electronic spin of the nitrogen vacancy (NV) center in diamond forms an atomically sized, highly sensitive sensor for magnetic fields. To harness the full potential of individual NV centers for sensing with high sensitivity and nanoscale spatial resolution, NV centers have to be incorporated into scanning probe structures enabling controlled scanning in close proximity to the sample surface. Here, we present an optimized procedure to fabricate single-crystal, all-diamond scanning probes starting from commercially available diamond and show a highly efficient and robust approach for integrating these devices in a generic atomic force microscope. Our scanning probes consisting of a scanning nanopillar (200 nm diameter, 1–2 μm length) on a thin (<1 μm) cantilever structure enable efficient light extraction from diamond in combination with a high magnetic field sensitivity (ηAC≈50±20nT/Hz). As a first application of our scanning probes, we image the magnetic stray field of a single Ni nanorod. We show that this stray field can be approximated by a single dipole and estimate the NV-to-sample distance to a few tens of nanometer, which sets the achievable resolution of our scanning probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Probing condensed matter physics with magnetometry based on nitrogen-vacancy centres in diamond
Casola, F., van der Sar, T., & Yacoby, A. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.88 · Cited by 635
Probing magnetism in 2D materials at the nanoscale with single-spin microscopy
Thiel, L., Wang, Z., Tschudin, M. A., Rohner, D., Gutiérrez-Lezama, I., Ubrig, N., Gibertini, M., Giannini, E., Morpurgo, A. F., & Maletinsky, P. (2019) · Science · doi:10.1126/science.aav6926 · Cited by 501
Self-citationPurely antiferromagnetic magnetoelectric random access memory
Kosub, T., Kopte, M., Hühne, R., Appel, P., Shields, B., Maletinsky, P., Hübner, R., Liedke, M. O., Fassbender, J., Schmidt, O. G., et al. (2017) · Nature Communications · doi:10.1038/ncomms13985 · Cited by 305
Self-citationAshfold, M. N. R., Goss, J. P., Green, B. L., May, P. W., Newton, M. E., & Peaker, C. V. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00518 · Cited by 284
Riedel, D., Söllner, I., Shields, B. J., Starosielec, S., Appel, P., Neu, E., Maletinsky, P., & Warburton, R. J. (2017) · Physical Review X · doi:10.1103/physrevx.7.031040 · Cited by 200
Self-citation
Metadata
- Authors
- Appel, P., Neu, E., Ganzhorn, M., Barfuss, A., Batzer, M., Gratz, M., Tschöpe, A., & Maletinsky, P.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2016-06-01
- Volume
- 87
- Issue
- 6
- Pages
- 063703-063703
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2331332256
- Cited by
- 171
- References
- 0
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of all diamond scanning probes for nanoscale magnetometry. https://app.cochat.ai/papers/10.1063/1.4952953
- The paper
- Appel, P., Neu, E., Ganzhorn, M., Barfuss, A., Batzer, M., Gratz, M., Tschöpe, A., & Maletinsky, P. (2016). Fabrication of all diamond scanning probes for nanoscale magnetometry. Review of Scientific Instruments. https://doi.org/10.1063/1.4952953
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.