Nonlinear ultrasound imaging of nanoscale acoustic biomolecules
Open accessThe DOI matches its Crossref record.
Abstract
Ultrasound imaging is widely used to probe the mechanical structure of tissues and visualize blood flow. However, the ability of ultrasound to observe specific molecular and cellular signals is limited. Recently, a unique class of gas-filled protein nanostructures called gas vesicles (GVs) was introduced as nanoscale (∼250 nm) contrast agents for ultrasound, accompanied by the possibilities of genetic engineering, imaging of targets outside the vasculature and monitoring of cellular signals such as gene expression. These possibilities would be aided by methods to discriminate GV-generated ultrasound signals from anatomical background. Here, we show that the nonlinear response of engineered GVs to acoustic pressure enables selective imaging of these nanostructures using a tailored amplitude modulation strategy. Finite element modeling predicted a strongly nonlinear mechanical deformation and acoustic response to ultrasound in engineered GVs. This response was confirmed with ultrasound measurements in the range of 10 to 25 MHz. An amplitude modulation pulse sequence based on this nonlinear response allows engineered GVs to be distinguished from linear scatterers and other GV types with a contrast ratio greater than 11.5 dB. We demonstrate the effectiveness of this nonlinear imaging strategy in vitro, in cellulo, and in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acoustic reporter genes for noninvasive imaging of microorganisms in mammalian hosts
Bourdeau, R. W., Lee-Gosselin, A., Lakshmanan, A., Farhadi, A., Kumar, S. R., Nety, S. P., & Shapiro, M. G. (2018) · Nature · doi:10.1038/nature25021 · Cited by 396
Self-citationUltrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Ultrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 249
Self-citationUltrasound imaging of gene expression in mammalian cells
Farhadi, A., Ho, G. H., Sawyer, D. P., Bourdeau, R. W., & Shapiro, M. G. (2019) · Science · doi:10.1126/science.aax4804 · Cited by 242
“For each ray line, the amplitude modulation (AM) code was implemented using one transmit with all elements in the active aperture followed by 2 transmits in which first the odd- and then the even-numbered elements are silenced (10).”
BackgroundMethodInfluentialSelf-citationUltrasound Contrast Agent Modeling: A Review
Versluis, M., Stride, E., Lajoinie, G., Dollet, B., & Segers, T. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.04.014 · Cited by 233
Metadata
- Authors
- Maresca, D., Lakshmanan, A., Lee-Gosselin, A., Melis, J. M., Ni, Y.-L., Bourdeau, R. W., Kochmann, D. M., & Shapiro, M. G.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2017-02-13
- Volume
- 110
- Issue
- 7
- Pages
- 073704-073704
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2587992644
- Cited by
- 112
- References
- 0
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonlinear ultrasound imaging of nanoscale acoustic biomolecules. https://app.cochat.ai/papers/10.1063/1.4976105
- The paper
- Maresca, D., Lakshmanan, A., Lee-Gosselin, A., Melis, J. M., Ni, Y.-L., Bourdeau, R. W., Kochmann, D. M., & Shapiro, M. G. (2017). Nonlinear ultrasound imaging of nanoscale acoustic biomolecules. Applied Physics Letters. https://doi.org/10.1063/1.4976105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.