Techniques for precise energy calibration of particle pixel detectors
Open accessThe DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Abstract
We demonstrate techniques to improve the accuracy of the energy calibration of Timepix pixel detectors, used for the measurement of energetic particles. The typical signal from such particles spreads among many pixels due to charge sharing effects. As a consequence, the deposited energy in each pixel cannot be reconstructed unless the detector is calibrated, limiting the usability of such signals for calibration. To avoid this shortcoming, we calibrate using low energy X-rays. However, charge sharing effects still occur, resulting in part of the energy being deposited in adjacent pixels and possibly lost. This systematic error in the calibration process results in an error of about 5% in the energy measurements of calibrated devices. We use FLUKA simulations to assess the magnitude of charge sharing effects, allowing a corrected energy calibration to be performed on several Timepix pixel detectors and resulting in substantial improvement in energy deposition measurements. Next, we address shortcomings in calibration associated with the huge range (from kiloelectron-volts to megaelectron-volts) of energy deposited per pixel which result in a nonlinear energy response over the full range. We introduce a new method to characterize the non-linear response of the Timepix detectors at high input energies. We demonstrate improvement using a broad range of particle types and energies, showing that the new method reduces the energy measurement errors, in some cases by more than 90%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Each Timepix is calibrated over a wide energy range from a minimum detectable threshold of 5-keV X-rays through to heavy ions of 500 keV µm−1 to ensure performance measuring the GCR environment45–47.”
From Space radiation measurements during the Artemis I lunar mission (2024) · cites this paper as [46]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536
The FLUKA Code: Developments and Challenges for High Energy and Medical Applications
Böhlen, T. T., Cerutti, F., Chin, M. P. W., Fassò, A., Ferrari, A., Ortega, P. G., Mairani, A., Sala, P. R., Smirnov, G., & Vlachoudis, V. (2014) · Nuclear Data Sheets · doi:10.1016/j.nds.2014.07.049 · Cited by 1,758
Llopart, X., Ballabriga, R., Campbell, M., Tlustos, L., & Wong, W. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.08.079 · Cited by 1,046
Precise energy calibration of pixel detector working in time-over-threshold mode
Jakubek, J. (2011) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2010.06.183 · Cited by 279
Pixel detectors with local intelligence: an IC designer point of view
Krummenacher, F. (1991) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(91)90152-g · Cited by 256
Holý, T., Heijne, E. H. M., Jakubek, J., Pospı́šil, S., Uher, J., & Vykydal, Z. (2008) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2008.03.074 · Cited by 109
Timepix-based radiation environment monitor measurements aboard the International Space Station
Stoffle, N., Pinsky, L. S., Kroupa, M., Hoang, S. M., Idárraga, J., Amberboy, C., Rios, R. R., Hauss, J., Keller, J., Bahadori, A. A., et al. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.02.016 · Cited by 91
Self-citation10 years of the Medipix2 Collaboration
Campbell, M. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.06.106 · Cited by 86
Energy-sensitive X-ray radiography and charge sharing effect in pixelated detector
Jakubek, J. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2009.03.148 · Cited by 78
A semiconductor radiation imaging pixel detector for space radiation dosimetry
Kroupa, M., Bahadori, A. A., Campbell-Ricketts, T., Empl, A., Hoang, S. M., Idárraga, J., Rios, R. R., Semones, E., Stoffle, N., Tlustos, L., et al. (2015) · Life Sciences in Space Research · doi:10.1016/j.lssr.2015.06.006 · Cited by 68
Self-citationCampbell, M., Heijne, E. H. M., Holý, T., Idárraga, J., Jakubek, J., Lebel, C., Leroy, C., Llopart, X., Pospı́šil, S., Tlustos, L., et al. (2008) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2008.03.096 · Cited by 55
Bouchami, J., Gutierrez, A., Houdayer, A., Idárraga, J., Jakubek, J., Lebel, C., Leroy, C., Martin, J.-P., Platkevič, M., & Pospı́šil, S. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2009.03.147 · Cited by 20
Kroupa, M., Hoang, S. M., Stoffle, N., Soukup, P., Jakubek, J., & Pinsky, L. S. (2014) · Journal of Instrumentation · doi:10.1088/1748-0221/9/05/c05008 · Cited by 17
Self-citationLET Estimation of Heavy Ion Particles based on a Timepix-Based Si Detector
Hoang, S. M., Pinsky, L. S., Vilalta, R., & Jakubek, J. (2012) · Journal of Physics Conference Series · doi:10.1088/1742-6596/396/2/022023 · Cited by 12
Charge collection characterization with semiconductor pixel detector timepix
Kroupa, M., Jakubek, J., & Krejci, F. (2008) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2008.4775163 · Cited by 9
Self-citationBattery-operated Independent Radiation Detector Data Report from Exploration Flight Test 1
Bahadori, A. A., Semones, E., Gaza, R., Kroupa, M., Rios, R. R., Stoffle, N., Campbell-Ricketts, T., Pinsky, L. S., & TURECEK, D. (2015) · K-State Research Exchange (Kansas State University) · Cited by 7
Self-citationMedipix in space on-board the ISS
Pinsky, L., Idárraga, J., Kroupa, M., Son, H. M., Stoffle, N., Semones, E., Bahadori, A. A., TURECEK, D., ̆il, S. P., Jakubek, J., et al. (2014) · Journal of Radiation Research · doi:10.1093/jrr/rrt197 · Cited by 6
Self-citationA PATTERN RECOGNITION APPROACH TO LEARNING TRACKS OF HEAVY-ION PARTICLES IN TIMEPIX DETECTORS
Hoang, S. M. (2013) · Cited by 5
Cited by
Jannis, D., Hofer, C. K., Gao, C., Xie, X., Béché, A., Pennycook, T. J., & Verbeeck, J. (2021) · Ultramicroscopy · doi:10.1016/j.ultramic.2021.113423 · Cited by 101
Resolving power of pixel detector Timepix for wide-range electron, proton and ion detection
Granja, C. D. S., Jakubek, J., Polansky, Š., Zach, V., Krist, P., Chvátil, D., Štursa, J., Sommer, M., Ploc, O., Kodaira, S., et al. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.08.014 · Cited by 74
ICRU Report 98, Stochastic Nature of Radiation Interactions: Microdosimetry
Braby, L. A., Conte, V., Dingfelder, M., GOODHEAD, D. T., Pinsky, L. S., Rosenfeld, A. B., Sato, T., Waker, A. J., Guatelli, S., Magrin, G., et al. (2023) · Journal of the ICRU · doi:10.1177/14736691231211380 · Cited by 78
Space radiation measurements during the Artemis I lunar mission
George, S. P., Gaza, R., Matthiä, D., Laramore, D., Lehti, J., Campbell-Ricketts, T., Kroupa, M., Stoffle, N., Marsalek, K., Przybyla, B., et al. (2024) · Nature · doi:10.1038/s41586-024-07927-7 · Cited by 47
“…of the reference October 1989 solar-particle event shows a fourfold peak dose rate difference between HERA detectors in the crew and the ‘storm shelter’ of 414 µGy min −1 to 95 µGy min −1 , with the discrepancy attributable to the more energetic spectrum of the inner belt (Supplementary Fig.”
Self-citationGranja, C. D. S., Kudela, K., Jakubek, J., Krist, P., Chvátil, D., Štursa, J., & Polansky, Š. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.09.140 · Cited by 37
Metadata
- Authors
- Kroupa, M., Campbell-Ricketts, T., Bahadori, A., & Empl, A.
- Affiliations
- Kansas State University (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2017-03-01
- Volume
- 88
- Issue
- 3
- Pages
- 033301-033301
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2596431638
- Cited by
- 26
- References
- 19
- Citations by year
- 2026: 1 · 2024: 4 · 2023: 5 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 4 · 2018: 6 · 2017: 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed (publishedVersion)
- K-State Research Exchange (Kansas State University) (submittedVersion)
- Funders
- Johnson Space Center (Bioastronautics, Human Health and Performance Contract)
- Topics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Detection and Scintillator Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
- Keywords
- energy calibration, charge sharing, low-energy X-rays, FLUKA simulation, energy deposition, energetic particles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.