Microwave-assisted synthesis of iron oxide nanoparticles in biocompatible organic environment
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The development of magnetite and maghemite particles in uniform nanometer size has triggered the interest of the research community due to their many interesting properties leading to a wide range of applications, such as catalysis, nanomedicine-nanobiology and other engineering applications. In this study, a simple, time-saving and low energy-consuming, microwave-assisted synthesis of iron oxide nanoparticles, is presented. The nanoparticles were prepared by microwave-assisted synthesis using polyethylene glycol (PEG) or PEG and β-cyclodextrin (β-CD)/water solutions of chloride salts of iron in the presence of ammonia solution. The prepared nano-powders were characterized using X-Ray Diffraction (XRD), Transition Electron Microscopy (TEM), Fourier-transform Infrared Spectroscopy (FTIR), Raman Spectroscopy, Vibrating Sample Magnetometer (VSM), X-Ray Photoelectron Spectroscopy (XPS) and Thermal analysis (TG/DSC). The produced nanoparticles are crystallized mostly in the magnetite and maghemite lattice exhibiting very similar shape and size, with indications of partial PEG coating. Heating time, microwave power and presence of PEG, are the key factors shaping the size properties of nanoparticles. The average size of particles ranges from 10.3 to 19.2 nm. The nanoparticles exhibit a faceted morphology, with zero contamination levels. The magnetic measurements indicate that the powders are soft magnetic materials with negligible coercivity and remanence, illustrating super-paramagnetic behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biesinger, M. C., Payne, B. P., Grosvenor, A. P., Lau, L. W. M., Gerson, A. R., & Smart, R. S. C. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2010.10.051 · Cited by 11,640
Cited by
Testa-Anta, M., Ramos-Docampo, M. A., Comesaña-Hermo, M., Rivas-Murias, B., & Salgueiriño, V. (2019) · Nanoscale Advances · doi:10.1039/c9na00064j · Cited by 298
Magnetic Nanoparticles as MRI Contrast Agents
Avasthi, A., Caro, C., Pozo-Torres, E., Leal, M. P., & García-Martín, M. L. (2020) · Topics in Current Chemistry · doi:10.1007/s41061-020-00302-w · Cited by 253
Magnetic Iron Nanoparticles: Synthesis, Surface Enhancements, and Biological Challenges
Vargas-Ortiz, J. R., Gonzalez, C., & Esquivel, K. (2022) · Processes · doi:10.3390/pr10112282 · Cited by 62
Optimization of Microalga Chlorella vulgaris Magnetic Harvesting
Savvidou, M. G., Dardavila, M. M., Georgiopoulou, I., Louli, V., Stamatis, H., Kekos, D., & Voutsas, E. (2021) · Nanomaterials · doi:10.3390/nano11061614 · Cited by 54
“From these results, it is evident that the particles follow a unhysteretic loop, illustrating superparamagnetic behavior at room temperature, thus indicating that their size is below 35 nm [39], which is verified in our case as the particles demonstrate an average diameter of 20 nm.”
BackgroundApplications and Efficacy of Iron Oxide Nanoparticles in the Treatment of Brain Tumors
Varalli, L., Berlet, R., Abenojar, E., McDaid, J., Gascoigne, D. A., Bailes, J., & Aksenov, D. P. (2025) · Pharmaceutics · doi:10.3390/pharmaceutics17040499 · Cited by 23
Metadata
- Authors
- Aivazoglou, E., Metaxa, E., & Hristoforou, E.
- Venue
- AIP Advances
- Publisher
- AIP Publishing
- Published
- 2017-10-13
- Volume
- 8
- Issue
- 4
- ISSN
- 2158-3226 (ISSN-L)
- OpenAlex
- W2763537434
- Cited by
- 97
- References
- 1
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.