Cited by 9Power Quality and HarmonicsOptimal Power Flow DistributionMicrogrid Control and Optimization

Rooftop PV systems with distributed batteries for voltage unbalance mitigation in low voltage radial feeders

Nour, Ahmed M. M., Hatata, Ahmed Y., Helal, Ahmed A., El-Saadawi, Magdi M.·2018·Journal of Renewable and Sustainable Energy

Abstract

This paper discusses the alleviation of voltage unbalance (VU) in low voltage four-wire ungrounded distribution networks. Unbalanced allocation of distributed rooftop Photovoltaic (PV) ratings and loads creates considerable neutral current in the neutral line. Because of the size limitation or non-connection of distributed batteries, this paper proposes three strategies for using the available distributed energy storage to reduce VU and neutral potential under a high penetration of distributed rooftop PVs. VU mitigation algorithms are presented and implemented in the MATLAB/software environment.

Integrity signals

Registry

Crossref · 10.1063/1.5034000

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Nour, A. M. M., Hatata, A. Y., Helal, A. A., & El-Saadawi, M. M.
Affiliations
  • Alexandria Higher Institute of Engineering and Technology (EG)
  • Mansoura University (EG)
  • Arab Academy for Science, Technology, and Maritime Transport (EG)
  • Department of Electrical Engineering, Mansoura University 2 , Mansoura City, Egypt
Venue
Journal of Renewable and Sustainable Energy
Published
2018-09-01
Volume
10
Issue
5
ISSN
1941-7012 (ISSN-L)
OpenAlex
W2890115151
Cited by
9
References
0
Citations by year
2023: 2 · 2021: 1 · 2020: 5 · 2019: 1
FWCI
0.67
Type
journal article
Language
en
Open access
closed
Locations
Journal of Renewable and Sustainable Energy (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
Keywords
voltage unbalance mitigation, rooftop photovoltaic systems, distributed energy storage, low-voltage distribution networks, neutral current, radial distribution feeders, photovoltaic penetration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review