Weak electric-field detection with sub-1 Hz resolution at radio frequencies using a Rydberg atom-based mixer
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Rydberg atoms have been used for measuring radio-frequency (RF) electric (E)-fields due to their strong dipole moments over the frequency range of 500 MHz-1 THz. For this, electromagnetically induced transparency (EIT) within the Autler-Townes (AT) regime is used such that the detected E-field is proportional to AT splitting. However, for weak E-fields AT peak separation becomes unresolvable thus limiting the minimum detectable E-field. Here, we demonstrate using the Rydberg atoms as an RF mixer for weak E-field detection well below the AT regime with frequency discrimination better than 1 Hz resolution. A heterodyne detection scenario with two E-fields incident on a vapor cell filled with cesium atoms is used. One E-field at 19.626000 GHz drives the 34D5/2 → 35P3/2 Rydberg transition and acts as a local oscillator (LO) and a second signal E-field (Sig) of interest is at 19.626090 GHz. In the presence of the LO, the Rydberg atoms naturally down convert the Sig field to a 90 kHz intermediate frequency (IF) signal. This IF signal manifests as an oscillation in the probe laser intensity through the Rydberg vapor and is easily detected with a photodiode and lock-in amplifier. In the configuration used here, E-field strength down to ≈ 46 μV/m ± 2 μV/m were detected with a sensitivity of ≈ 79 μVm−1Hz−1/2. Furthermore, neighboring fields 0.1 Hz away and equal in strength to Sig could be discriminated without any leakage into the lock-in signal. For signals 1 Hz away and as high as +60 dB above Sig, leakage into the lock-in signal could be kept below -3 dB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electromagnetically induced transparency: Optics in coherent media
Fleischhauer, M., Imamoglu, A., & Marangos, J. P. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.633 · Cited by 5,189
Stark Effect in Rapidly Varying Fields
Autler, S. H., & Townes, C. H. (1955) · Physical Review · doi:10.1103/physrev.100.703 · Cited by 1,878
Microwave electrometry with Rydberg atoms in a vapour cell using bright atomic resonances
Sedlacek, J. A., Schwettmann, A., Kübler, H., Löw, R., Pfau, T., & Shaffer, J. P. (2012) · Nature Physics · doi:10.1038/nphys2423 · Cited by 863
Mohapatra, A. K., Jackson, T. R., & Adams, C. S. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.113003 · Cited by 665
Broadband Rydberg Atom-Based Electric-Field Probe for SI-Traceable, Self-Calibrated Measurements
Holloway, C. L., Gordon, J. A., Jefferts, S., Schwarzkopf, A., Anderson, D. A., Miller, S. A., Thaicharoen, N., & Raithel, G. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2360208 · Cited by 449
Self-citationAtom-Based Vector Microwave Electrometry Using Rubidium Rydberg Atoms in a Vapor Cell
Sedlacek, J. A., Schwettmann, A., Kübler, H., & Shaffer, J. P. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.063001 · Cited by 383
Holloway, C. L., Gordon, J. A., Schwarzkopf, A., Anderson, D. A., Miller, S. A., Thaicharoen, N., & Raithel, G. (2014) · Applied Physics Letters · doi:10.1063/1.4883635 · Cited by 228
Self-citationAtom-Based Sensing of Weak Radio Frequency Electric Fields Using Homodyne Readout
Kumar, S., Fan, H., Kübler, H., Sheng, J., & Shaffer, J. P. (2017) · Scientific Reports · doi:10.1038/srep42981 · Cited by 197
Quantum-Limited Atomic Receiver in the Electrically Small Regime
Cox, K. C., Meyer, D. H., Fatemi, F. K., & Kunz, P. D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.110502 · Cited by 185
Subwavelength microwave electric-field imaging using Rydberg atoms inside atomic vapor cells
Fan, H. Q., Kumar, S., Daschner, R., Kübler, H., & Shaffer, J. P. (2014) · Optics Letters · doi:10.1364/ol.39.003030 · Cited by 179
Holloway, C. L., Simons, M. T., Gordon, J. A., Wilson, P. F., Cooke, C. M., Anderson, D. A., & Raithel, G. (2017) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2016.2644616 · Cited by 158
Self-citationEffect of Vapor-Cell Geometry on Rydberg-Atom-Based Measurements of Radio-Frequency Electric Fields
Fan, H., Kumar, S., Sheng, J., Shaffer, J. P., Holloway, C. L., & Gordon, J. A. (2015) · Physical Review Applied · doi:10.1103/physrevapplied.4.044015 · Cited by 146
Self-citationMicrowave dressing of Rydberg dark states
Танаситтикосол, М., Pritchard, J. D., Maxwell, D., Gauguet, A., Weatherill, K. J., Potvliege, R. M., & Adams, C. S. (2011) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/44/18/184020 · Cited by 133
Cavity-enhanced microwave electric field measurement using Rydberg atoms
Peng, Y., Wang, J., Yang, A., Jia, Z., Li, D., & Chen, B. (2018) · Journal of the Optical Society of America B · doi:10.1364/josab.35.002272 · Cited by 41
Metadata
- Authors
- Gordon, J. A., Simons, M. T., Haddab, A. H., & Holloway, C. L.
- Venue
- AIP Advances
- Publisher
- AIP Publishing
- Published
- 2019-04-01
- Volume
- 9
- Issue
- 4
- ISSN
- 2158-3226 (ISSN-L)
- OpenAlex
- W2925320673
- Cited by
- 178
- References
- 14
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.