Cryogenic goniometer for measurements in pulsed magnetic fields fabricated via additive manufacturing technique
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Complex high-precision mechanical devices can be fabricated using a three-dimensional printing technology with the help of computer-aided design. Using 3D stereolithography, we have constructed a cryogenic goniometer for measurements in pulsed magnetic fields of up to 100 T, at temperatures as low as 0.5 K. We review the properties of several materials tested in developing the goniometer and report on its design and performance. The goniometer allows samples to be rotated in situ to a precision of 0.2° so that the field can be applied at many different angles to the samples’ symmetry directions. Following its success, we establish that 3D printing is now a viable technology for pulsed field and other cryogenic probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gibson, I., Rosen, D., & Stucker, B. (2015) · doi:10.1007/978-1-4939-2113-3 · Cited by 3,299
From rapid prototyping to home fabrication: How 3D printing is changing business model innovation
Rayna, T., & Striukova, L. (2016) · Technological Forecasting and Social Change · doi:10.1016/j.techfore.2015.07.023 · Cited by 816
Status and Development of Pulsed Magnets at the NHMFL Pulsed Field Facility
Nguyen, D. N., Michel, J. R., & Mielke, C. H. (2016) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2016.2515982 · Cited by 78
Mielke, C. H., Singleton, J., Nam, M.-S., Harrison, N., Agosta, C. C., Fravel, B. W., & Montgomery, L. K. (2001) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/13/36/308 · Cited by 75
Self-citationGoddard, P., Blundell, S. J., Singleton, J., McDonald, R., Ardavan, A., Narduzzo, A., Schlueter, J. A., Kini, A. M., & Sasaki, T. (2004) · Physical Review B · doi:10.1103/physrevb.69.174509 · Cited by 61
Self-citationGraf, D. E., Stillwell, R. L., Purcell, K. M., & Tozer, S. W. (2011) · High Pressure Research · doi:10.1080/08957959.2011.633909 · Cited by 45
Very low friction rotator for use at low temperatures and high magnetic fields
Palm, E. C., & Murphy, T. P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149571 · Cited by 31
Low Temperature Sample Holder Providing Two Degrees of Freedom in a Solenoid
Brennert, G. F., Reed, W. A., & Fawcett, E. (1965) · Review of Scientific Instruments · doi:10.1063/1.1719873 · Cited by 25
Tan, B. S., Harrison, N., Zhu, Z., Balakirev, F., Ramshaw, B. J., Srivastava, A., Sabok-Sayr, S. A., Dąbrowski, B., Lonzarich, G. G., & Sebastian, S. E. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1504164112 · Cited by 21
Self-citationPiezoelectrically driven rotator for use in high magnetic fields at low temperatures
Ohmichi, E., Nagai, S., Maeno, Y., Ishiguro, T., MIZUNO, H., & Nagamura, T. (2001) · Review of Scientific Instruments · doi:10.1063/1.1347982 · Cited by 14
Research works printed but not linked: 4
- Council, 2013, High Magnetic Field Science and Its Application in the United States: Current Status and Future Directions
- Troughton, 2009, Handbook of Plastics Joining, 345
- K. R. Shirer, Y. Sun, M. D. Bachmann, C. Putzke, T. Helm, L. E. Winter, F. F. Balakirev, R. D. McDonald, J. G. Analytis, N. L. Nair, E. D. Bauer, F. Ronning, C. Felser, T. Meng, B. Yan, and P. J. W. Moll, arXiv:1808.00403 (2018). · arXiv
- 2015, Additive Manufacturing Technologies
Cited by
Orphan high field superconductivity in non-superconducting uranium ditelluride
Frank, C. E., Lewin, S. K., Saucedo Salas, G., Czajka, P., Hayes, I. M., Yoon, H., Metz, T., Paglione, J., Singleton, J., & Butch, N. P. (2024) · Nature Communications · doi:10.1038/s41467-024-47090-1 · Cited by 21
Self-citationSudden adiabaticity signals reentrant bulk superconductivity in UTe2
Schönemann, R., Rosa, P. F. S., Thomas, S. M., Lai, Y., Nguyen, D. N., Singleton, J., Brosha, E. L., McDonald, R., Zapf, V. S., Maiorov, B., et al. (2023) · PNAS Nexus · doi:10.1093/pnasnexus/pgad428 · Cited by 19
Self-citationQuantum-limit phenomena and band structure in the magnetic topological semimetal EuZn2As2
Blawat, J. M., Speer, S., Singleton, J., Xie, W., & Jin, R. (2023) · Communications Physics · doi:10.1038/s42005-023-01378-8 · Cited by 9
Self-citationLarge magnetoresistance and quantum oscillations observed in superconducting β -IrSn 4
Speer, S., Pershin, Y. V., Blawat, J. M., Singleton, J., & Jin, R. (2026) · Journal of Physics Condensed Matter · doi:10.1088/1361-648x/ae3c4a · Cited by 3
“The coil was mounted on a cryogenic goniometer that permits precise in-situ rotation at temperatures down to 0.5 K [34].”
InfluentialSelf-citationVu, D., Lee, H., Nicoletti, D., Wei, W., Jin, Z., Chichinadze, D. V., Buzzi, M., Li, W., Yang, X., Wu, R., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-70254-0 · Cited by 8
Metadata
- Authors
- Willis, X., Ding, X., Singleton, J., & Balakirev, F. F.
- Affiliations
- Los Alamos National Laboratory (US)
- Corresponding author
- Balakirev, Fedor F.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2020-03-01
- Volume
- 91
- Issue
- 3
- Pages
- 036102-036102
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W3009158918
- Cited by
- 9
- References
- 15
- Citations by year
- 2026: 3 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 1
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- National Science Foundation (DMR-1157490)
- Topics
- Physical Sciences › Engineering › Industrial and Manufacturing Engineering › Additive Manufacturing and 3D Printing Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Advanced Condensed Matter Physics
- Keywords
- pulsed magnetic field, stereolithography, 3D printing, additive manufacturing, cryogenic probe, sample rotation, low-temperature materials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cryogenic goniometer for measurements in pulsed magnetic fields fabricated via additive manufacturing technique. https://app.cochat.ai/papers/10.1063/1.5125792
- The paper
- Willis, X., Ding, X., Singleton, J., & Balakirev, F. F. (2020). Cryogenic goniometer for measurements in pulsed magnetic fields fabricated via additive manufacturing technique. Review of Scientific Instruments. https://doi.org/10.1063/1.5125792
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.