The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A 3D-printed microfluidic-enabled hollow microneedle architecture for transdermal drug delivery
Open accessAbstract
Embedding microfluidic architectures with microneedles enables fluid management capabilities that present new degrees of freedom for transdermal drug delivery. To this end, fabrication schemes that can simultaneously create and integrate complex millimeter/centimeter-long microfluidic structures and micrometer-scale microneedle features are necessary. Accordingly, three-dimensional (3D) printing techniques are suitable candidates because they allow the rapid realization of customizable yet intricate microfluidic and microneedle features. However, previously reported 3D-printing approaches utilized costly instrumentation that lacked the desired versatility to print both features in a single step and the throughput to render components within distinct length-scales. Here, for the first time in literature, we devise a fabrication scheme to create hollow microneedles interfaced with microfluidic structures in a single step. Our method utilizes stereolithography 3D-printing and pushes its boundaries (achieving print resolutions below the full width half maximum laser spot size resolution) to create complex architectures with lower cost and higher print speed and throughput than previously reported methods. To demonstrate a potential application, a microfluidic-enabled microneedle architecture was printed to render hydrodynamic mixing and transdermal drug delivery within a single device. The presented architectures can be adopted in future biomedical devices to facilitate new modes of operations for transdermal drug delivery applications such as combinational therapy for preclinical testing of biologic treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidic Platform for Controlled Synthesis of Polymeric Nanoparticles
Karnik, R., Gu, F., Basto, P., Cannizzaro, C., Dean, L., Kyei-Manu, W., Langer, R., & Farokhzad, O. C. (2008) · Nano Letters · doi:10.1021/nl801736q · Cited by 887
Cited by
Vat photopolymerization 3D printing for advanced drug delivery and medical device applications
Xu, X., Awad, A., Robles-Martinez, P., Gaisford, S., Goyanes, A., & Basit, A. W. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.10.008 · Cited by 370
Hollow microneedles: A perspective in biomedical applications
Cárcamo-Martínez, Á., Mallon, B., Domínguez-Robles, J., Vora, L. K., Anjani, Q. K., & Donnelly, R. F. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120455 · Cited by 285
Lyu, S., Dong, Z., Xu, X., Bei, H.-P., Yuen, H.-Y., James Cheung, C.-W., Wong, M.-S., He, Y., & Zhao, X. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.003 · Cited by 266
Kwon, K., Kim, J. U., Deng, Y., Krishnan, S. R., Choi, J., Jang, H., Lee, K., Su, C.-J., Yoo, I., Wu, Y., et al. (2021) · Nature Electronics · doi:10.1038/s41928-021-00556-2 · Cited by 230
Lab-on-chip technology for chronic disease diagnosis
Wu, J., Dong, M., Rigatto, C., Liu, Y., & Lin, F. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0014-0 · Cited by 170
Metadata
- Authors
- Yeung, C., Chen, S., King, B., Lin, H., King, K., Akhtar, F., Diaz, G., Wang, B., Zhu, J., Sun, W., Khademhosseini, A., & Emaminejad, S.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2019-11-01
- Volume
- 13
- Issue
- 6
- Pages
- 064125-064125
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2994992793
- Cited by
- 217
- References
- 1
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.