Cited by 4Adsorption and Cooling SystemsChemical Looping and Thermochemical ProcessesPhase Change Materials Research

Experimental analysis of Indonesian natural zeolites-water pair for closed system adsorption thermal energy storage

Nasruddin, Arsyad, A. P., Djubaedah, Wulandari, D. A., Hidayat, H. F.·2020·AIP Conference Proceedings

Abstract

Adsorption thermal energy storage has reversible reaction which are exothermic in adsorption direction and endothermic in desorption reaction. This system is a promising technology for the storage of intermittent energy, such as solar power and industrial waste heat. During the adsorption reaction, heats are released and calculated as the amount of energy that can be stored. Natural zeolite is a potential adsorbent due to its porous structure, high surface area, and ability to adsorb small molecule such as water. In this paper, we analyze the storage performance of adsorption thermal energy storage using natural zeolite-water as a pair for charging temperature of 160 °C. As the result, natural zeolite-water offer a potential storage density as adsorption thermal energy storage with energy storage density of 63.94 kWh/m3. Furthermore, natural zeolite can be developed as it can be modified to enhance its ability to adsorb water and store energy.

Integrity signals

Registry

Crossref · 10.1063/5.0013934

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Natural Indonesian zeolite showed a temperature lift of 50 °C and an energy storage density of 63.94 kW/m3, lower than synthetic zeolite 13X or alumina but higher than water or silica gel.

    “They observed a temperature lift of 50°C and an energy storage density of 63.94 kW/m3, which is lower than the one obtained with synthetic zeolite 13X or alumina but higher than the one achievable with water or silica gel.”
  • Zeolites are suitable as adsorbents for thermal energy storage systems because of their hydrophilic properties and ability to store a large amount of heat of adsorption.

    “Zeolites seem to be the perfect candidates as adsorbents for TES systems because of their hydrophilic properties and their ability to store a huge amount of heat, which is a heat of adsorption (Nasruddin et al. 2020).”

Cited by

Sorted by citations

Authors
Nasruddin, Arsyad, A. P., Djubaedah, Wulandari, D. A., & Hidayat, H. F.
Affiliations
University of Indonesia (ID)
Venue
AIP Conference Proceedings
Published
2020
Volume
2259
Pages
040036
ISSN
0094-243X (ISSN-L)
OpenAlex
W3083618612
Cited by
4
References
0
Citations by year
2026: 1 · 2024: 1 · 2023: 1 · 2022: 1
FWCI
1.23
Type
conference paper
Language
en
Open access
closed
Locations
AIP conference proceedings (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Chemical Looping and Thermochemical Processes
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
Keywords
natural zeolite, closed systems, energy storage density, water adsorption, solar energy storage, industrial waste heat, zeolite modification

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review