Detecting telecom single photons with 99.5−2.07+0.5% system detection efficiency and high time resolution

Open access
Chang, J., Los, J. W. N., Tenorio-Pearl, J. O., Noordzij, N., Gourgues, R., Guardiani, A., Zichi, J. R., Pereira, S. F., Urbach, H. P., Zwiller, V., Dorenbos, S. N., Esmaeil Zadeh, I.·2021·APL Photonics

Abstract

Single photon detectors are indispensable tools in optics, from fundamental measurements to quantum information processing. The ability of superconducting nanowire single photon detectors (SNSPDs) to detect single photons with unprecedented efficiency, short dead time, and high time resolution over a large frequency range enabled major advances in quantum optics. However, combining near-unity system detection efficiency (SDE) with high timing performance remains an outstanding challenge. In this work, we fabricated novel SNSPDs on membranes with 99.5−2.07+0.5% SDE at 1350 nm with 32 ps timing jitter (using a room-temperature amplifier), and other detectors in the same batch showed 94%–98% SDE at 1260–1625 nm with 15–26 ps timing jitter (using cryogenic amplifiers). The SiO2/Au membrane enables broadband absorption in small SNSPDs, offering high detection efficiency in combination with high timing performance. With low-noise cryogenic amplifiers operated in the same cryostat, our efficient detectors reach a timing jitter in the range of 15–26 ps. We discuss the prime challenges in optical design, device fabrication, and accurate and reliable detection efficiency measurements to achieve high performance single photon detection. As a result, the fast developing fields of quantum information science, quantum metrology, infrared imaging, and quantum networks will greatly benefit from this far-reaching quantum detection technology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/5.0039772

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 234

Metadata

Authors
Chang, J., Los, J. W. N., Tenorio-Pearl, J. O., Noordzij, N., Gourgues, R., Guardiani, A., Zichi, J. R., Pereira, S. F., Urbach, H. P., Zwiller, V., Dorenbos, S. N., & Esmaeil Zadeh, I.
Venue
APL Photonics
Published
2021-03-01
Volume
6
Issue
3
ISSN
2378-0967 (ISSN-L)
OpenAlex
W3105205584
Cited by
234
References
6
FWCI
19.48
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detecting telecom single photons with 99.5−2.07+0.5% system detection efficiency and high time resolution. https://app.cochat.ai/papers/10.1063/5.0039772
The paper
Chang, J., Los, J. W. N., Tenorio-Pearl, J. O., Noordzij, N., Gourgues, R., Guardiani, A., Zichi, J. R., Pereira, S. F., Urbach, H. P., Zwiller, V., Dorenbos, S. N., & Esmaeil Zadeh, I. (2021). Detecting telecom single photons with 99.5−2.07+0.5% system detection efficiency and high time resolution. APL Photonics. https://doi.org/10.1063/5.0039772

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.