The DOI matches its Crossref record; the references it cites are not checked yet.
Thermally stable Peltier controlled vacuum chamber for electrical transport measurements
Abstract
The design, manufacture, and characterization of an inexpensive, temperature-controlled vacuum chamber with millikelvin stability for electrical transport measurements at and near room temperature is reported. A commercially available Peltier device and a high-precision temperature controller are used to actively heat and cool the sample space. The system was designed to minimize thermal fluctuations in spintronic and semiconductor transport measurements, but the general principle is relevant to a wide range of electrical measurement applications. The main issues overcome are the mounting of a sample with a path of high thermal conductivity through to the Peltier device and the heat sinking of the said Peltier device inside a vacuum. A copper slug is used as the mount for a sample, and a large copper block is used as a thermal feedthrough before a passive heat sink is used to cool this block. The Peltier device provides 20 W of heating and cooling power, achieving a maximum range of 30 K below and 40 K above the ambient temperature. The temperature stability is within 5 mK at all set points with an even better performance above the ambient temperature. A vacuum pressure of 10−8 hPa is achievable. As a demonstration, we present experimental results from current-induced electrical switching of a CuMnAs thin film. Transport measurements with and without the Peltier control emphasize the importance of a constant temperature in these applications. The thermal lag between the sample space measurement and the sample itself is observed through magnetoresistance values measured during a temperature sweep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 3
Research works printed but not linked: 18
- 2018, Nat. Phys., 14, 220, 10.1038/s41567-018-0062-7 · DOI · Paper page
- 2020, J. Phys. D: Appl. Phys., 53, 453001, 10.1088/1361-6463/ab9d98 · DOI · Paper page
- 2021, IEEE Trans. Magn., 57, 800439, 10.1109/tmag.2021.3078583 · DOI · Paper page
- 2021, Adv. Funct. Mater., 31, 2006773, 10.1002/adfm.202006773 · DOI · Paper page
- 2018, Annu. Rev. Phys. Chem., 69, 299, 10.1146/annurev-physchem-050317-021353 · DOI · Paper page
- 2021, Mater. Today Phys., 21, 100519, 10.1016/j.mtphys.2021.100519 · DOI · Paper page
- 2023, Fluid Dyn. Mater. Process., 19, 187, 10.32604/fdmp.2022.020351 · doi:10.32604/fdmp.2022.020351
- 1987, Rev. Sci. Instrum., 58, 2110, 10.1063/1.1139472 · doi:10.1063/1.1139472
- 1997, Rev. Sci. Instrum., 68, 4163, 10.1063/1.1148362 · doi:10.1063/1.1148362
- 2020, Rev. Sci. Instrum., 91, 033904, 10.1063/1.5134737 · doi:10.1063/1.5134737
- 2012, Rev. Sci. Instrum., 83, 043903, 10.1063/1.3700217 · DOI
- 2016, Science, 351, 587, 10.1126/science.aab1031 · DOI · Paper page
- 2017, Phys. Rev. Lett., 118, 057701, 10.1103/physrevlett.118.057701 · DOI
- 2017, Nat. Commun., 8, 15434, 10.1038/ncomms15434 · DOI
- 2019, Phys. Rev. Appl., 12, 064003, 10.1103/physrevapplied.12.064003 · doi:10.1103/physrevapplied.12.064003
- 2021, Nat. Electron., 4, 30, 10.1038/s41928-020-00506-4 · DOI
- 2013, Nat. Commun., 4, 2322, 10.1038/ncomms3322 · DOI
- L. Barton , “Sb doped CuMnAs for antiferromagnetic spintronics,” Ph.D. thesis, University of Nottingham, 2023.
Metadata
- Authors
- Poole, S. F., Amin, O. J., Solomon, A., Barton, L. X., Campion, R. P., Edmonds, K. W., & Wadley, P.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2024-03-01
- Volume
- 95
- Issue
- 3
- ISSN
- 0034-6748
- 1089-7623
- Cited by
- 3
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0/ (vor, 5 d)
- creativecommons.org/licenses/by/4.0/ (tdm, 5 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermally stable Peltier controlled vacuum chamber for electrical transport measurements. https://app.cochat.ai/papers/10.1063/5.0186155
- The paper
- Poole, S. F., Amin, O. J., Solomon, A., Barton, L. X., Campion, R. P., Edmonds, K. W., & Wadley, P. (2024). Thermally stable Peltier controlled vacuum chamber for electrical transport measurements. Review of Scientific Instruments. https://doi.org/10.1063/5.0186155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.