Cities and Energy: Urban Morphology and Residential Heat-Energy Demand
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Our aim is better understanding of the theoretical heat-energy demand of different types of urban form at a scale of 500 m × 500 m. The empirical basis of this study includes samples of dominant residential building typologies identified for Paris, London, Berlin, and Istanbul. In addition, archetypal idealised samples were created for each type through an analysis of their built form parameters and the removal of unwanted ‘invasive’ morphologies. The digital elevation models of these real and idealised samples were run through a simulation that modelled solar gains and building surface energy losses to estimate heat-energy demand. In addition to investigating the effect of macroscale morphological parameters, microscale design parameters, such as U-values and glazing ratios, as well as climatic effects were analysed. The theoretical results of this study suggest that urban-morphology-induced heat-energy efficiency is significant and can lead to a difference in heat-energy demand of up to a factor of six. Compact and tall building types were found to have the greatest heat-energy efficiency at the neighbourhood scale while detached housing was found to have the lowest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 2×
“In the developed world, approximately 40 per cent of energy end-use takes place in buildings, while in the developing world the figure is still significant at 20 per cent (Pérez-Lombard et al., 2008).”
BackgroundModeling of end-use energy consumption in the residential sector: A review of modeling techniques
Swan, L. G., & Ugursal, V. I. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.033 · Cited by 1,934
Energy consumption and urban texture
Ratti, C., Baker, N., & Steemers, K. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2004.10.010 · Cited by 628 · cited 6×
“…and Steemers, 2000) and incorporating parameters to approximate factors such as occupant behaviour, systems efficiency, and insulation standards (U-values), Ratti et al (2005a; 2005b) were able to automate the calculation of building energy demand at the hitherto impracticable neighbourhood scale.”
BackgroundMethodResultInfluentialAchieving Sustainable Urban Form
Willams, N. (2001) · Land Use Policy · doi:10.1016/s0264-8377(01)00010-2 · Cited by 577
Energy and the city: density, buildings and transport
Steemers, K. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(02)00075-0 · Cited by 483 · cited 5×
“For passive solar house standards, Steemers (2003) highlights a 22 per cent increase in heating energy for a 30 degree obstruction of a southfacing façade compared to an unobstructed façade. At the same time he refers to Yannas (1994) who find 40 per cent higher heat savings when comparing apartments with detached”
BackgroundInfluentialSpatial distribution of urban building energy consumption by end use
Howard, B., Parshall, L., Thompson, J., Hammer, S., Dickinson, J., & Modi, V. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2011.10.061 · Cited by 428 · cited 5×
“At the same time, by incorporating tools to calculate and display the solar volume for any given plot, Capeluto and Shaviv (2001) were able to demonstrate that even at relatively high built densities—floor area ratios (FARs) of around 1.6–1.8—it was possible to maintain solar access rights to all buildings in a neighb…”
BackgroundMethodInfluentialState of the world's cities, 2008/2009: harmonious cities
(2009) · Choice Reviews Online · doi:10.5860/choice.46-4749 · Cited by 313
Urban density and energy consumption: a new look at old statistics
Mindali, O., Raveh, A., & Salomon, I. (2004) · Transportation Research Part A: Policy and Practice · doi:10.1016/j.tra.2003.10.004 · Cited by 308 · cited 1×
“…as important trade-off factors (Hui, 2001), and the possibility that the relationship between density and efficiency may not be causal (Lariviere and Lafrance, 1999; Steemers, 2003) while others generally subscribe to the concept of ‘density equals efficiency’ (Holden, 2004; Mindali, 2004).”
BackgroundModelling the electricity consumption of cities: effect of urban density
Larivière, I., & Lafrance, G. (1999) · Energy Economics · doi:10.1016/s0140-9883(98)00007-3 · Cited by 232 · cited 2×
“Martin (1967; 1972), March and Trace (1969) investigated the relationships between surface coverage, building height, building depth and density to understand the equivalent levels of day lighting.”
BackgroundDomestic energy fact file 2003
Shorrock, L. D., & Utley, J. (2003) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 224
Urban Form, Density and Solar Potential
Cheng, V., Steemers, K., Montavon, M., & Compagnon, R. (2006) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 218
Solar radiation modelling in the urban context
Robinson, D., & Stone, A. (2004) · Solar Energy · doi:10.1016/j.solener.2004.05.010 · Cited by 206 · cited 1×
“Most importantly however, models were optimised to become radically more scalable given the finite availability of computing resources (Mardaljevic and Rylatt, 2003; Robinson and Stone, 2004).”
BackgroundSalat, S. (2009) · Building Research & Information · doi:10.1080/09613210903162126 · Cited by 206 · cited 2×
“Perhaps closest to a general study was the work conducted by APUR (2007) and the CSTB (Salat, 2009) into the thermal performance of the Parisian building stock.”
BackgroundMethodEcological footprints and sustainable urban form
Holden, E. (2004) · Journal of Housing and the Built Environment · doi:10.1023/b:joho.0000017708.98013.cb · Cited by 186 · cited 2×
“…as important trade-off factors (Hui, 2001), and the possibility that the relationship between density and efficiency may not be causal (Lariviere and Lafrance, 1999; Steemers, 2003) while others generally subscribe to the concept of ‘density equals efficiency’ (Holden, 2004; Mindali, 2004).”
BackgroundLow energy building design in high density urban cities
Hui, S. C. M. (2001) · Renewable Energy · doi:10.1016/s0960-1481(01)00049-0 · Cited by 170 · cited 2×
“Some highlight the negative impacts of density on natural light, solar gain, and ventilation as important trade-off factors (Hui, 2001), and the possibility that the relationship between density and efficiency may not be causal (Lariviere and Lafrance, 1999; Steemers, 2003) while others generally…”
BackgroundA holistic approach to energy efficient building forms
Okeil, A. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.03.013 · Cited by 170 · cited 2×
“Okeil (2010) performed a comparison for three types of urban form, described as linear, block, and residential solar block (RSB).”
BackgroundUrban texture analysis with image processing techniques: winds and dispersion
Ratti, C., Sabatino, S. D., & Britter, R. E. (2005) · Theoretical and Applied Climatology · doi:10.1007/s00704-005-0146-z · Cited by 133 · cited 6×
“…and Steemers, 2000) and incorporating parameters to approximate factors such as occupant behaviour, systems efficiency, and insulation standards (U-values), Ratti et al (2005a; 2005b) were able to automate the calculation of building energy demand at the hitherto impracticable neighbourhood scale.”
BackgroundMethodResultInfluentialEnergy conservation through building design
Watson, D. G. (1979) · Cited by 125
Urban morphology and indicators of radiation availability
Robinson, D. (2006) · Solar Energy · doi:10.1016/j.solener.2006.01.007 · Cited by 124 · cited 1×
“The desire to apply the learning from such work practically led Baker and Steemers to develop the ‘lighting and thermal’ (LT) method (Baker and Steemers, 1995; 1996; 2000; Roaf and Hancock, 1992).”
MethodUrban Texture Analysis with Image Processing Techniques
Ratti, C., & Richens, P. (1999) · Springer eBooks · doi:10.1007/978-1-4615-5047-1_4 · Cited by 107 · cited 1×
“Numerical modelling tools for investigating the neighbourhood scale were further honed by Ratti and Richens (1999) with the addition of new functions that could calculate built form statistics from the DEM; including surface coverage, average built height, sky view factors, and shadows.”
MethodLT Method 3.0 — a strategic energy-design tool for Southern Europe
Baker, N. V., & Steemers, K. (1996) · Energy and Buildings · doi:10.1016/0378-7788(95)00950-7 · Cited by 64 · cited 2×
“The desire to apply the learning from such work practically led Baker and Steemers to develop the ‘lighting and thermal’ (LT) method (Baker and Steemers, 1995; 1996; 2000; Roaf and Hancock, 1992).”
Method
Cited by
Giridharan, R., & Emmanuel, R. (2018) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.01.024 · Cited by 218
“There is evidence from heating load ‐ dominated cities that urban compactness is advantageous to reduce heating energy demand (e.g. Rode et al., 2014).”
Cool pavements for urban heat island mitigation: A synthetic review
Wang, C., Wang, Z.-H., Kaloush, K. E., & Shacat, J. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111171 · Cited by 214
Accelerated environmental performance-driven urban design with generative adversarial network
Huang, C., Zhang, G., Yao, J., Wang, X., Calautit, J. K., Zhao, C., An, N., & Peng, X. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109575 · Cited by 159
Spatial measures and methods in sustainable urban morphology: A systematic review
Zhang, P., Ghosh, D., & Park, S. (2023) · Landscape and Urban Planning · doi:10.1016/j.landurbplan.2023.104776 · Cited by 159
Upscaling urban data science for global climate solutions
Creutzig, F., Lohrey, S., Bai, X., Baklanov, A., Dawson, R., Dhakal, S., Lamb, W. F., McPhearson, T., Minx, J., Munoz, E., et al. (2019) · Global Sustainability · doi:10.1017/sus.2018.16 · Cited by 137
Metadata
- Authors
- Rode, P., Keim, C., Robazza, G., Viejo, P., & Schofield, J.
- Venue
- Environment and Planning B: Planning and Design
- Publisher
- SAGE Publications
- Published
- 2014-02
- Volume
- 41
- Issue
- 1
- Pages
- 138-162
- ISSN
- 0265-8135 (ISSN-L)
- 1472-3417
- OpenAlex
- W2092394546
- Cited by
- 245
- References
- 21
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.