Acuity of Sound Localisation: A Topography of Auditory Space. II. Pinna Cues Absent
The DOI matches its Crossref record.
Abstract
The acuity of azimuth and elevation discrimination was measured under conditions in which the cues to localisation provided by the pinnae were removed. Four subjects localised a sound source (white noise through a speaker) which varied in position over a range of elevations (-40° to +40°) and azimuths (0° to 180°), at 10° intervals, on the left side of the head. Pinna cues were removed by the insertion of individually cast moulds in both pinnae. Each mould had an access hole to the auditory canal. The absolute and algebraic, azimuth and elevation errors were measured for all subjects at each position of the source. The variability of azimuth and elevation error was also computed. The performance of the subjects was compared to their performance under normal hearing conditions. Insertion of the pinnae moulds was found to increase substantially elevation error and the number of front/back reversals. The importance of the cues provided by the pinnae in these discriminations was thus confirmed. However, the increase in elevation error did not result in a corresponding increase in azimuth error. These findings provide support for the proposition that azimuth and elevation discrimination are coded independently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
3-D sound for virtual reality and multimedia
Madole, D., & Begault, D. (1995) · Computer Music Journal · doi:10.2307/3680997 · Cited by 868
Relearning sound localization with new ears
Hofman, P. M., Van Riswick, J. G. A., & Van Opstal, A. J. (1998) · Nature Neuroscience · doi:10.1038/1633 · Cited by 436
A Spatial Hearing Deficit in Early-Blind Humans
Zwiers, M. P., Van Opstal, A. J., & Cruysberg, J. R. M. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-09-j0002.2001 · Cited by 277
(2001) · Journal of the Audio Engineering Society · Cited by 245
Contribution of spectral cues to human sound localization
Langendijk, E. H. A., & Bronkhorst, A. W. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1501901 · Cited by 206
Contribution of Head Shadow and Pinna Cues to Chronic Monaural Sound Localization
Van Wanrooij, M. M., & Van Opstal, A. J. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.0048-04.2004 · Cited by 195
“After application of a unilateral or binaural mold, their azimuth localization responses are not affected (data not shown in this study, but see Oldfield and Parker, 1984; Hofman and Van Opstal, 2003), whereas manipulation of spectral cues in a virtual set-up has little influence on lateral angle…”
BackgroundMethodInfluentialThe nature and distribution of errors in sound localization by human listeners
Carlile, S., Leong, P., & Hyams, S. (1997) · Hearing Research · doi:10.1016/s0378-5955(97)00161-5 · Cited by 193
Spectro-temporal factors in two-dimensional human sound localization
Hofman, P. M., & Van Opstal, A. J. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.422784 · Cited by 187
Training-Induced Plasticity of Auditory Localization in Adult Mammals
Kacelnik, O., Nodal, F. R., Parsons, C. H., & King, A. J. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040071 · Cited by 178
“Direct evidence for this is provided by our finding that modifying the spectral cues provided by the open ear reduced the localization accuracy of ferrets that had adapted to occlusion of the other ear to the level observed when the earplug was first introduced. Because the same unilateral manipulation of the spectral…”
BackgroundPerceptual recalibration in human sound localization: Learning to remediate front-back reversals
Zahorik, P., Bangayan, P., Sundareswaran, V., Wang, K., & Tam, C. (2006) · The Journal of the Acoustical Society of America · doi:10.1121/1.2208429 · Cited by 101
Metadata
- Authors
- Oldfield, S. R., & Parker, S. P. A.
- Venue
- Perception
- Publisher
- SAGE Publications
- Published
- 1984-10
- Volume
- 13
- Issue
- 5
- Pages
- 601-617
- ISSN
- 0301-0066 (ISSN-L)
- 1468-4233
- OpenAlex
- W2078089693
- Cited by
- 112
- References
- 0
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.