Effects of Room Reflectance and Background Noise on Perceived Auditory Distance
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Perceptions of egocentric auditory distance were investigated within an environment for which the reverberation time could be systematically varied without changes in the size or shape of the room. Two levels of wide-band background noise, differing by 20 dB, were used as a masking stimulus. Target sounds were presented from distances between 0.75 and 6.0 m and verbal reports of distance were collected from 288 listeners in two separate experiments. Changes in physical distance produced variation in reported distance in each configuration. Reported distance was generally proportional to real distance, but considerably underestimated when room reflectance was low. When room reflectance was high ( T 60 ≈ 1.7 s for the range of frequencies used), initial reports of distance were often overestimates; upon repeated presentation, judgments in the high reflectance room became more nearly veridical. The effect of increasing the background noise level was to decrease the perceived distance. These findings are in accord with expectations based upon the importance of reverberation cue(s) to distance and upon previous analyses from this laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rank transformations as a bridge between parametric and nonparametric statistics
Conover, W. J., & Iman, R. L. (1981) · The American Statistician · doi:10.1080/00031305.1981.10479327 · Cited by 3,922
Cited by
Naguib, M., & Wiley, R. H. (2001) · Animal Behaviour · doi:10.1006/anbe.2001.1860 · Cited by 310
Assessing auditory distance perception using virtual acoustics
Zahorik, P. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1458027 · Cited by 303
Kolarik, A. J., Moore, B. C. J., Zahorik, P., Cirstea, S., & Pardhan, S. (2016) · Attention, Perception, & Psychophysics · doi:10.3758/s13414-015-1015-1 · Cited by 297
A summary of research investigating echolocation abilities of blind and sighted humans
Kolarik, A. J., Cirstea, S., Pardhan, S., & Moore, B. C. J. (2014) · Hearing Research · doi:10.1016/j.heares.2014.01.010 · Cited by 270
Human echolocation as a basic form of perception and action
Stroffregen, T. A., & Pittenger, J. B. (1995) · Ecological Psychology · doi:10.1207/s15326969eco0703_2 · Cited by 169
Metadata
- Authors
- Mershon, D. H., Ballenger, W. L., Little, A. D., McMurtry, P. L., & Buchanan, J. L.
- Venue
- Perception
- Publisher
- SAGE Publications
- Published
- 1989-06
- Volume
- 18
- Issue
- 3
- Pages
- 403-416
- ISSN
- 0301-0066 (ISSN-L)
- 1468-4233
- OpenAlex
- W2075229564
- Cited by
- 112
- References
- 1
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.