Expanded dynamic range of fluorescent indicators for Ca 2+ by circularly permuted yellow fluorescent proteins
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Fluorescence resonance energy transfer (FRET) technology has been used to develop genetically encoded fluorescent indicators for various cellular functions. Although most indicators have cyan- and yellow-emitting fluorescent proteins (CFP and YFP) as FRET donor and acceptor, their poor dynamic range often prevents detection of subtle but significant signals. Here, we optimized the relative orientation of the two chromophores in the Ca(2+) indicator, yellow cameleon (YC), by fusing YFP at different angles. We generated circularly permuted YFPs (cpYFPs) that showed efficient maturation and acid stability. One of the cpYFPs incorporated in YC absorbs a great amount of excited energy from CFP in its Ca(2+)-saturated form, thereby increasing the Ca(2+)-dependent change in the ratio of YFP/CFP by nearly 600%. Both in cultured cells and in the nervous system of transgenic mice, the new YC enables visualization of subcellular Ca(2+) dynamics with better spatial and temporal resolution than before. Our study provides an important guide for the development and improvement of indicators using GFP-based FRET.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ratiometric imaging using FRET-based calcium indicators, such as yellow cameleon (YC) indicators (Horikawa et al., 2010; Nagai et al., 2004; Yamada et al., 2011), is another approach that has the advantage of reduced sensitivity to motion artifacts and essentially permits quantification of calcium concentration levels.”
From Transgenic mice for intersectional targeting of neural sensors and effectors with high specificity and performance (2015) · cites this paper as Nagai et al., 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Efficient selection for high-expression transfectants with a novel eukaryotic vector
Hitoshi, N., Ken-ichi, Y., & Jun-ichi, M. (1991) · Gene · doi:10.1016/0378-1119(91)90434-d · Cited by 5,134
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Self-citationNagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753
Self-citationA high signal-to-noise Ca2+ probe composed of a single green fluorescent protein
Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616
Reducing the Environmental Sensitivity of Yellow Fluorescent Protein
Griesbeck, O., Baird, G. S., Campbell, R. E., Zacharias, D. A., & Tsien, R. Y. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m102815200 · Cited by 1,023
Circularly permuted green fluorescent proteins engineered to sense Ca 2+
Nagai, T., Sawano, A., Park, E. S., & Miyawaki, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051636098 · Cited by 966
Self-citationCircular permutation and receptor insertion within green fluorescent proteins
Baird, G. S., Zacharias, D. A., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.20.11241 · Cited by 961
Dynamic and quantitative Ca 2+ measurements using improved cameleons
Miyawaki, A., Griesbeck, O., Heim, R., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2135 · Cited by 823
Self-citationVisualization of the Spatial and Temporal Dynamics of Intracellular Signaling
Miyawaki, A. (2003) · Developmental Cell · doi:10.1016/s1534-5807(03)00060-1 · Cited by 455
Self-citation
Cited by
Items 801–900 of 1,000
Chang, T.-J., Lai, W.-Q., Chang, Y., Wang, C.-L., & Yang, D. (2021) · Journal of the Chinese Medical Association · doi:10.1097/jcma.0000000000000574 · Cited by 7
Zhang, M., Cao, H., Hou, L., Song, S., Zeng, J., & Pei, Y. (2017) · Plant Cell Reports · doi:10.1007/s00299-017-2122-3 · Cited by 7
Smigielski, L., Aguilar, G. B., Kwaaitaal, M. A. C. J., Zhang, W., & Thordal‐Christensen, H. (2019) · Cellular Microbiology · doi:10.1111/cmi.13091 · Cited by 7
“6 sequence was amplified from the pcDNA3 vector (Nagai et al., 2004) using Gateway compatible primers (Table S1) by PCR and using a Gateway BP reaction recombined into pDONR201.”
MethodmCerulean3-Based Cameleon Sensor to Explore Mitochondrial Ca2+ Dynamics In Vivo
Greotti, E., Fortunati, I., Pendin, D., Ferrante, C., Galla, L., Zentilin, L., Giacca, M., Kaludercic, N., Sante, M. D., Mariotti, L., et al. (2019) · iScience · doi:10.1016/j.isci.2019.07.031 · Cited by 7
Jalink, K. (2005) · Nature Methods · doi:10.1038/nmeth0106-11 · Cited by 7
Mechanics & Dynamics of the Primary Cilium
Battle, C. (2013) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-4037 · Cited by 7
Somoza, S. C., Boccardo, N. A., Santin, F., Sede, A. R., Wengier, D. L., Boisson‐Dernier, A., & Muschietti, J. P. (2024) · Biomolecules · doi:10.3390/biom14111375 · Cited by 6
Chronic Two-Photon Imaging of Neural Activity in the Anesthetized and Awake Behaving Rodent
Margolis, D. J., Lütcke, H., Helmchen, F., Weber, B., & Haiss, F. (2013) · Neuromethods · doi:10.1007/978-1-62703-785-3_10 · Cited by 7
Transcriptional Genetically Encoded Calcium Indicators inDrosophila
Bansal, S., & Lin, S. (2022) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top107797 · Cited by 6
Xenopus oocyte plasma membrane sheets for FRET analysis
Ottolia, M., Philipson, K. D., & John, S. (2006) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00435.2006 · Cited by 6
“Specific targeting of these constructs to the ER (CFP-ER), Golgi (CFP-Golgi), and plasma mem- AJP-Cell Physiol • VOL 292 • APRIL 2007 • www.ajpcell.org brane (YFP-PM) was achieved by fusing the fluorescent proteins to the ER targeting sequence of calreticulin (Clontech) (1), the sequence encoding the NH2-terminal 81 a…”
InfluentialChristophe Boss, A., Marchi, U. D., Hermant, A., Conrad, M., Sizzano, F., Palini, A. G., Wiederkehr, A., & Bouche, N. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600869 · Cited by 6
Tvrdík, P., & Capecchi, M. R. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-369497-3.10002-0 · Cited by 7
Development of intensiometric indicators for visualizing N-cadherin interaction across cells
Kanadome, T., Hayashi, K., Seto, Y., Eiraku, M., Nakajima, K., Nagai, T., & Matsuda, T. (2022) · Communications Biology · doi:10.1038/s42003-022-04023-2 · Cited by 6
Self-citationBurri, J. T., Munglani, G., Nelson, B. J., Grossniklaus, U., & Vogler, H. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0672-8_20 · Cited by 6
Lee, Y. F., Lariviere, L., Russ, A., Choi, S., Bacskai, B. J., & Kastanenka, K. V. (2021) · eNeuro · doi:10.1523/eneuro.0389-20.2021 · Cited by 6
“A genetically encoded calcium indicator, YellowCameleon 3.6 (Nagai et al., 2004) was virally expressed in cortical neurons (Fig.”
BackgroundInfluentialVisualizing and Quantifying Data from Time-Lapse Imaging Experiments
Mahlandt, E. K., & Goedhart, J. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2051-9_19 · Cited by 6
Kumagai, Y., Kamioka, Y., Yagi, S., Matsuda, M., & Kiyokawa, E. (2011) · Analytical Biochemistry · doi:10.1016/j.ab.2011.02.021 · Cited by 6
Fluorescent Protein-based Biosensors to Visualize Signal Transduction beneath the Plasma Membrane
Fujioka, Y., Nanbo, A., Nishide, S., & Ohba, Y. (2015) · Analytical Sciences · doi:10.2116/analsci.31.267 · Cited by 5
Sasaki, K., & Yoshida, M. (2016) · Drug Discovery Today Technologies · doi:10.1016/j.ddtec.2016.06.001 · Cited by 5
Nakai, N., Sato, K., Tani, T., Kawagishi, M., Ka, H., Saito, K., & Terada, S. (2021) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2021.05.088 · Cited by 5
Directed evolution of the genetically encoded zinc(II) FRET sensor ZapCY1
Wei, T., Huang, S., Hu, Q., Wang, J., Huo, Z., Liu, C., Lu, S., & Chen, H. (2022) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2022.130201 · Cited by 5
Stable wide-field voltage imaging for observing neuronal plasticity at the neuronal network level
Tominaga, T., Kajiwara, R., & Tominaga, Y. (2023) · Biophysics and Physicobiology · doi:10.2142/biophysico.bppb-v20.0015 · Cited by 5
Self-citationLuo, Y., Pi, S., & Liu, Y. (2024) · ChemPhysChem · doi:10.1002/cphc.202300973 · Cited by 5
Dernič, J., Eleftheriou, A., Vasilikos, L., Rauch, M., Imseng, P., Zanker, H. S., Looser, Z. J., Meister, R., Moros, F. V., Kagan, T., et al. (2025) · Communications Biology · doi:10.1038/s42003-025-08677-6 · Cited by 5
Time-deterministic cryo-optical microscopy
Tsuji, K., Yamanaka, M., Kumamoto, Y., Tamura, S., Miyamura, W., Kubo, T., Mizushima, K., Kono, K., Hirano, H., Shiozaki, M., et al. (2025) · Light Science & Applications · doi:10.1038/s41377-025-01941-8 · Cited by 6
Self-citationIn Vivo Functional Imaging of the Olfactory Bulb at Single-Cell Resolution
Fink, S., Kovalchuk, Y., Homma, R., Schwendele, B., Direnberger, S., Cohen, L. B., Griesbeck, O., & Garaschuk, O. (2011) · Neuromethods · doi:10.1007/7657_2011_1 · Cited by 5
Miyamoto, A., Bannai, H., Michikawa, T., & Mikoshiba, K. (2013) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2013.02.112 · Cited by 5
Monitoring Calcium Levels With Genetically Encoded Indicators
Garaschuk, O., & Griesbeck, O. (2009) · Neuromethods · doi:10.1007/978-1-60761-476-0_5 · Cited by 5
Evans, T. A., Barkauskas, D. S., & Silver, J. (2019) · Experimental Neurology · doi:10.1016/j.expneurol.2019.112972 · Cited by 5
Integrin CD11b provides a new marker of pre-germinal center IgA+ B cells in murine Peyer’s patches
Gao, P., Adachi, T., Okai, S., Morita, N., Kitamura, D., & Shinkura, R. (2021) · International Immunology · doi:10.1093/intimm/dxab113 · Cited by 5
Yu, Z., Taylor, J. L., He, Y., & Ni, J. (2015) · Plant Signaling & Behavior · doi:10.1080/15592324.2015.1057366 · Cited by 5
A portable FRET analyzer for rapid detection of sugar content
Kim, H., Kim, H. S., Ha, J., & Lee, S. (2015) · The Analyst · doi:10.1039/c4an02195a · Cited by 5
Engineering and Application of Genetically Encoded Calcium Indicators
Akerboom, J., Tian, L., Marvin, J. S., & Looger, L. L. (2012) · Neuromethods · doi:10.1007/978-1-62703-014-4_8 · Cited by 5
Roelse, M., Wehrens, R., Henquet, M., Witkamp, R. F., Hall, R. D., & Jongsma, M. A. (2019) · Chemical Senses · doi:10.1093/chemse/bjz044 · Cited by 5
Cohn, J., Dwivedi, V. K., Valperga, G., Zarate, N., de Bono, M., Horvitz, H. R., & Pierce-Shimomura, J. T. (2019) · G3 Genes Genomes Genetics · doi:10.1534/g3.119.400654 · Cited by 5
“These proteins are regulated in a number of ways, such as transcriptionally (Oda et al. 2000; Nakano and Vousden 2001; Sturm et al. 2006; Borensztajn et al. 2007), post-transcriptionally (Ventura et al. 2008; Sherrard et al. 2017), and post-translationally (Verma et al. 2001; Lowman et al. 2010).”
BackgroundFuture Directions in Advanced Mycological Microscopy
Czymmek, K. J., & Dahms, T. E. S. (2015) · Fungal biology · doi:10.1007/978-3-319-22437-4_8 · Cited by 5
“60 (Nagai et al. 2004), the calmodulin-based [ ] Ca2+ c FRET sensor, in three economically important plant pathogenic fungi, Magnaporthe oryzae, Fusarium oxysporum, and Fusarium graminearum (Kim et al.”
BackgroundBiomimetic Chemical Sensing by Fluorescence Signals Using a Virus-like Particle-Based Platform
Kushida, Y., Arai, Y., Shimono, K., & Nagai, T. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00537 · Cited by 5
Self-citationFörster Resonance Energy Transfer ( FRET ) for Proteins
Chao, L. K., & Clegg, R. M. (2008) · Wiley eBooks · doi:10.1002/9780470048672.wecb171 · Cited by 5
Kalogeropoulou, E. (2018) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 6
Mimata, Y., Gong, R., Pei, X., Qin, G., & Ye, W. (2026) · Molecular Horticulture · doi:10.1186/s43897-025-00181-z · Cited by 4
Development of an Efficient FRET-Based Ratiometric Uranium Biosensor
Sauge‐Merle, S., Recuerda, M., Beccia, M. R., Lemaire, D., Cherif, R., BREMOND, N., Mérola, F., Bousmah, Y., & Berthomieu, C. (2023) · Biosensors · doi:10.3390/bios13050561 · Cited by 4
Bhattacharya, D., Mehle, A., Kamp, T. J., & Balijepalli, R. C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0131399 · Cited by 4
“Because FRET is dependent on both the distance separating the donor and acceptor as well as their relative orientation, it is not possible to calculate absolute changes in distances between donor and acceptor without verifying the orientations [52].”
BackgroundFRET with Fluorescent Proteins
Hoi, H., Ding, Y., & Campbell, R. E. (2013) · Wiley eBooks · doi:10.1002/9783527656028.ch11 · Cited by 4
Tsubota, H., Kinoshita, Y., Shigeno, M., & Hosoi, H. (2023) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.3c00881 · Cited by 4
Matsuda, T., Sakai, S., Okazaki, K.-I., & Nagai, T. (2024) · ACS Sensors · doi:10.1021/acssensors.3c02398 · Cited by 4
Self-citationGCaMP – a Family of Single-Fluorophore Genetically Encoded Calcium Indicators
Erofeev, A. I., Vinokurov, E. K., Власова, О. Л., & Борисович, Б. И. (2023) · Российский физиологический журнал им И М Сеченова · doi:10.31857/s0869813923070038 · Cited by 4
Electronic system for FRET based in vitro sensing of cytosolic Ca2+ in INS-1E pancreatic β-cells
Vinchhi, B., Christophe Boss, A., Conrad, M., Hermant, A., Marchi, U. D., Wiederkehr, A., Meurville, E., Bouche, N., & Dehollain, C. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348454 · Cited by 4
Greotti, E., & Pozzan, T. (2020) · BIO-PROTOCOL · doi:10.21769/bioprotoc.3504 · Cited by 4
“They have a circularly permuted Venus (cpV) as acceptor that improves the ratiometric sensitivity (Nagai et al., 2004), CaM and M13 have been mutated to lower interference with the endogenous protein (Palmer et al., 2006).”
BackgroundEvaluation of multi-color genetically encoded Ca2+ indicators in filamentous fungi
Kim, H.-S., Kim, J., Hwangbo, A., Akerboom, J., Looger, L. L., Duncan, R. L., Son, H., Czymmek, K. J., & Kang, S. (2021) · Fungal Genetics and Biology · doi:10.1016/j.fgb.2021.103540 · Cited by 4
Gam, J., Ha, J., Kim, H., Lee, D., Lee, J., & Lee, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.04.083 · Cited by 4
Slocum, J. D., Palmer, A. E., & Jimenez, R. (2019) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.9b02479 · Cited by 4
Measurement of cytoplasmic and cilioplasmic calcium in a single living cell
Sherpa, R. T., Pala, R., Mohieldin, A. M., & Nauli, S. M. (2019) · Methods in cell biology · doi:10.1016/bs.mcb.2019.03.015 · Cited by 4
Comparative Ca2+ channel contributions to intracellular Ca2+ levels in the circadian clock
Plante, A. E., Rao, V. P., Rizzo, M. A., & Meredith, A. L. (2021) · Biophysical Reports · doi:10.1016/j.bpr.2021.100005 · Cited by 4
Saito, K., Kobayashi, K., Tani, T., & Nagai, T. (2008) · Cell Structure and Function · doi:10.1247/csf.08015 · Cited by 4
“60) was reported previously (Nagai et al., 2004).”
BackgroundInfluentialSelf-citationGenetically Encoded FRET Indicators for Live-Cell Imaging of Histone Acetylation
Sasaki, K., & Yoshida, M. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-622-1_12 · Cited by 4
Imaging of Calcium Dynamics in Pollen Tube Cytoplasm
Barberini, M. L., & Muschietti, J. P. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-1902-4_4 · Cited by 4
“where “Kd′” is the apparent dissociation constant that is 250 nM according to [20].”
BackgroundInfluentialHelmchen, F. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9780511979958.010 · Cited by 4
Miyamoto, A., Sugiura, K., & Mikoshiba, K. (2016) · Cell Calcium · doi:10.1016/j.ceca.2016.09.007 · Cited by 4
Current Approaches for Engineering Proteins with Diverse Biological Properties
Li, I. T. S., Pham, E., & Truong, K. (2007) · Advances in experimental medicine and biology · doi:10.1007/978-0-387-76713-0_2 · Cited by 4
Lei, L. I., Zhou, J., Peng, W. A. N. G., Ma, C., Zhu, Z.-W., Gu, J., Zhu, C. X., Chen, G., Zhang, S., & Xu, J. (2019) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(18)61138-7 · Cited by 4
Hodgson, L. (2008) · ACS Chemical Biology · doi:10.1021/cb800136v · Cited by 4
Plant Viruses Can Alter Aphid-Triggered Calcium Elevations in Infected Leaves
Then, C., Bellegarde, F., Schivre, G., Martinière, A., Macia, J.-L., Xiong, T. C., & Drucker, M. (2021) · Cells · doi:10.3390/cells10123534 · Cited by 3
“6 is a well-characterized calcium sensor allowing the sensitive real-time measurement of free calcium levels in cells and tissues [22,23].”
BackgroundFasano, G., Petrini, S., Bonavolontà, V., Paradisi, G., Pedalino, C., Tartaglia, M., & Lauri, A. (2024) · Molecular Medicine · doi:10.1186/s10020-024-00807-w · Cited by 3
Illuminating compartmentalized AMPK signaling in single cells
Jhawar, A., Parks, K., & Schmitt, D. L. (2026) · Biochemical Journal · doi:10.1042/bcj20250267 · Cited by 3
“These biosensors demonstrate relatively modest dynamic range and diminished sensitivity when used to track kinase activity [35,36].”
Fluorescent Proteins for Neuronal Imaging
Zhao, Y., & Campbell, R. E. (2015) · Biological and medical physics, biomedical engineering · doi:10.1007/978-3-319-12913-6_3 · Cited by 3
Perspectives of FRET Imaging to Study Epigenetics and Mechanobiology in the Nucleus
Qin, P., Cheng, B., Lu, S., Chien, S., & Wang, Y. (2016) · Springer eBooks · doi:10.1007/978-1-4939-5617-3_7 · Cited by 3
Fluorescent Indicators for Functional Optical Imaging
Akemann, W., Mutoh, H., & Knöpfel, T. (2013) · Neuromethods · doi:10.1007/978-1-62703-785-3_4 · Cited by 4
Franck, C. M., Westermann, J., & Boisson‐Dernier, A. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7286-9_10 · Cited by 3
Neef, M., Hennig, A., Hausmann, N., & Hampp, R. (2011) · Cited by 3
Protein–Protein Interactions: Bimolecular Fluorescence Complementation and Cytology Two Hybrid
Purkait, D., Ilyas, M., & Atmakuri, K. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3445-5_16 · Cited by 3
Genetically-encoded temperature indicators for thermal biology
Wazawa, T., Ozaki-Noma, R., Kai, L., Fukushima, S., Matsuda, T., & Nagai, T. (2025) · Biophysics and Physicobiology · doi:10.2142/biophysico.bppb-v22.0008 · Cited by 3
Self-citationSpatiotemporal Quantification of Cytosolic pH in Arabidopsis Pollen Tubes
Portes, M. T., Damineli, D. S. C., & Feijó, J. A. (2021) · BIO-PROTOCOL · doi:10.21769/bioprotoc.4084 · Cited by 3
Olivocerebellar Somatotopy Revisited
Michikawa, T., & Miyawaki, A. (2021) · Contemporary clinical neuroscience · doi:10.1007/978-3-030-75817-2_6 · Cited by 3
Self-citationWormTensor: a clustering method for time-series whole-brain activity data from C. elegans
Tsuyuzaki, K., Yamamoto, K., Toyoshima, Y., Sato, H., Kanamori, M., Teramoto, T., Ishihara, T., Iino, Y., & Nikaido, I. (2023) · BMC Bioinformatics · doi:10.1186/s12859-023-05230-2 · Cited by 3
FRET‐Based Cellular Sensing with Genetically Encoded Fluorescent Indicators
Claussen, J. C., Hildebrandt, N., & Medintz, I. L. (2013) · Wiley eBooks · doi:10.1002/9783527656028.ch10 · Cited by 3
Rot fluoreszierende Proteine: spezielle Anwendungen in der Bildgebung und Perspektiven
Shcherbakova, D. M., Subach, O. M., & Verkhusha, V. V. (2012) · Angewandte Chemie · doi:10.1002/ange.201200408 · Cited by 3
Martin, J. (2012) · Neuromethods · doi:10.1007/978-1-62703-014-4_1 · Cited by 3
Heyde, K. C., & Ruder, W. C. (2016) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2016.2620942 · Cited by 3
A Yellow Fluorescent Protein with Reduced Chloride Sensitivity Engineered by Loop‐Insertion
Liang, J., Yang, Y., Yin, P., Ding, Y., Shen, Y., Qin, M., Wang, J., Xu, Q., Cao, Y., & Wang, W. (2013) · ChemBioChem · doi:10.1002/cbic.201300199 · Cited by 3
Fluorescence Microscopy Imaging in Biomedical Sciences
Sun, Y., & Periasamy, A. (2012) · Biological and medical physics series · doi:10.1007/978-3-642-28391-8_3 · Cited by 3
Rational Design of FRET-Based Sensor Proteins
Merkx, M. (2009) · Reviews in fluorescence · doi:10.1007/978-1-4419-1260-2_3 · Cited by 3
“A strategy that has been successfully applied in the optimization of several FRET sensors is the use of circularly permuted fluores-cent protein domains [13–15].”
Zhu, R., Hao, Z., Lou, H., Song, Y., Zhao, J., Zhu, J., & Chen, P. R. (2017) · Tetrahedron · doi:10.1016/j.tet.2017.05.039 · Cited by 3
Encapsulated Optically Responsive Cell Systems: Toward Smart Implants in Biomedicine
Christophe Boss, A., Bouche, N., & Marchi, U. D. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201701148 · Cited by 3
Diseño de un nuevo sensor de Ca²+ y su aplicación a los orgánulos intracelulares "ex vivo e in vivo"
Navarro, P. N. (2016) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/18635 · Cited by 3
An ensemble learning approach to auto-annotation for whole-brain C. elegans imagingPreprint
Wu, S., Toyoshima, Y., Jang, M. S., Kanamori, M., Teramoto, T., Iwasaki, Y., Ishihara, T., Iino, Y., & Yoshida, R. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/180430 · Cited by 3
Pietraszewska‐Bogiel, A., van Weeren, L., & Goedhart, J. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/771261 · Cited by 3
“6, Nagai et al. 2004), and the cAMP biosensor, EPAC (TEPACVV; Klarenbeek et al. 2011).”
A green light-excitable FRET system for monitoring intracellular calcium levels in plant cells
Yokawa, K., & Kodama, Y. (2021) · Plant Signaling & Behavior · doi:10.1080/15592324.2021.1963104 · Cited by 2
TRIC-A Facilitates Sarcoplasmic Reticulum–Mitochondrial Ca2+ Signaling Crosstalk in Cardiomyocytes
Li, A., Zhou, X., Park, K. H., Yi, J., Li, X., Ko, J., Chen, Y., Nishi, M., Yamazaki, D., Takeshima, H., et al. (2025) · Cells · doi:10.3390/cells14201579 · Cited by 2
“(2025a) Absolute mitochondrial Ca 2+ concentrations were calculated using the corrected ratio method [39], where 3, and n = 1.7 were from previous reports [40].”
InfluentialPagano, S., & Hodgson, L. (2026) · Cells · doi:10.3390/cells15040347 · Cited by 2
“The FRET-donor fluorescent protein is monomeric ECFP [31], and the acceptor is a circularly permuted monomeric Citrine-YFP [32,33], a configuration widely used in single-chain FRET biosensors to maximize dynamic range and sensitivity.”
Bossi, J. G., Barberini, M. L., Grenzi, M., Tortora, G., Santin, F., Bassi, A., Goutman, J., Obertello, M., Costa, A., Estevez, J. M., et al. (2026) · PLANT PHYSIOLOGY · doi:10.1093/plphys/kiag275 · Cited by 2
Ellis‐Davies, G. C. R., & Pugh, E. N. (2011) · The Journal of General Physiology · doi:10.1085/jgp.201110673 · Cited by 2
Yagi‐Utsumi, M., Miura, H., Ganser, C., Watanabe, H., Hiranyakorn, M., Satoh, T., Uchihashi, T., Kato, K., Okazaki, K.-I., & Aoki, K. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241612865 · Cited by 2
Interaction of Gravity with Cell Metabolism
Hanke, W. R. L., Kohn, F. P. M., Neef, M., & Hampp, R. (2018) · SpringerBriefs in space life sciences · doi:10.1007/978-3-030-00596-2_2 · Cited by 2
Imaging systemic calcium response and its molecular dissection using virus-induced gene silencing
Fernandez, J. C., & Gilroy, S. (2022) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2022.08.006 · Cited by 2
Studying Drosophila Larval Behavior in Agarose Channels
Greaney, M. R., & Heckscher, E. S. (2024) · Cold Spring Harbor Protocols · doi:10.1101/pdb.prot108420 · Cited by 2
Chemical and Biosensors Based on Graphene Materials
Yin, P. T., Kim, T. P., Choi, J., & Lee, K. (2014) · Wiley eBooks · doi:10.1002/9783527677788.ch10 · Cited by 2
Etxebeste, O., & Takeshita, N. (2015) · Fungal biology · doi:10.1007/978-3-319-22437-4_2 · Cited by 2
“2.2b; Nagai et al. 2004).”
Engineering Fluorescent Calcium Sensor Proteins for Imaging Neural Activity
Kim, D. S., Jayaraman, V., Looger, L. L., & Svoboda, K. (2014) · Cited by 2
Fluorescent resonance energy transfer -based biosensor for detecting conformational changes of Pin1
Hidaka, M., Okabe, E., Hatakeyama, K., Zook, H. N., Uchida, C., & Uchida, T. (2018) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2018.09.123 · Cited by 2
Pancreatic beta cell based optical biosensor and system for continuous glucose monitoring
Vinchhi, B., Agashe, N., Christophe Boss, A., Hermant, A., Bouche, N., Marchi, U. D., & Dehollain, C. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8919186 · Cited by 2
“The structures were connected through a peptide linker sequence (GTGGSGGGTGGSGGGT) [4].”
Background
Metadata
- Authors
- Nagai, T., Yamada, S., Tominaga, T., Ichikawa, M., & Miyawaki, A.
- Affiliations
- Kyoto University (JP)
- Corresponding author
- Miyawaki, Atsushi
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2004-07-09
- Volume
- 101
- Issue
- 29
- Pages
- 10554-10559
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC490022
- OpenAlex
- W1980726951
- Cited by
- 1,030
- References
- 15
- Citations by year
- 2026: 15 · 2025: 16 · 2024: 38 · 2023: 34 · 2022: 36 · 2021: 46 · 2020: 46 · 2019: 53 · 2018: 52 · 2017: 59 · 2016: 49 · 2015: 66 · 2014: 46 · 2013: 92 · 2012: 74
- FWCI
- 21.62
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Science and Technology Agency (CREST)
- Core Research for Evolutional Science and Technology
- Precursory Research for Embryonic Science and Technology
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Keywords
- calcium sensor, circularly permuted GFP, fluorescence resonance energy transfer, dynamic range, genetically encoded fluorescent indicators, chromophore orientation, transgenic mice
- MeSH terms
- Animals, Bacterial Proteins, Calcium, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Proteins, Microscopy, Fluorescence, Models, Molecular, Molecular Sequence Data, Protein Conformation, Fluorescence Resonance Energy Transfer, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.