The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fluorescent-conjugated polymer superquenching facilitates highly sensitive detection of proteases
Open accessAbstract
Sensor formats have been developed for detecting the activity of proteolytic enzymes based on fluorescent conjugated polymer superquenching. These sensors employ a reactive peptide sequence within a tether linking a quencher to a biotin. The peptide binds to sensors containing colocated biotin-binding protein and fluorescent polymer by means of biotin–biotin binding protein interactions, resulting in a strong quenching of polymer fluorescence. Enzyme-mediated cleavage of the peptide results in a reversal of the fluorescence quenching. These assays for protease activity are simple, sensitive, fast, and have the specificity required for screening chemical libraries for novel protease inhibitors in a high-throughput screening assay environment. These assays have been demonstrated for enterokinase, caspase-3/7, and β-secretase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The precursor of Alzheimer's disease amyloid A4 protein resembles a cell-surface receptor
Kang, J., Lemaire, H.-G., Unterbeck, A., Salbaum, J. M., Masters, C. L., Grzeschik, K.-H., Multhaup, G., Beyreuther, K., & Müller-Hill, B. (1987) · Nature · doi:10.1038/325733a0 · Cited by 4,619
Vassar, R., Bennett, B. D., Babu-Khan, S., Kahn, S., Mendiaz, E. A., Denis, P., Teplow, D. B., Ross, S., Amarante, P., Loeloff, R., et al. (1999) · Science · doi:10.1126/science.286.5440.735 · Cited by 3,876
Cited by
Chemical Sensors Based on Amplifying Fluorescent Conjugated Polymers
Thomas, S. W., Joly, G. D., & Swager, T. M. (2007) · Chemical Reviews · doi:10.1021/cr0501339 · Cited by 4,198
Sapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503873 · Cited by 1,561
Acetylenic Polymers: Syntheses, Structures, and Functions
Liu, J., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Reviews · doi:10.1021/cr900149d · Cited by 1,196
Gehlen, M. H. (2020) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2019.100338 · Cited by 734
Enzyme-responsive polymeric assemblies, nanoparticles and hydrogels
Hu, J., Zhang, G., & Liu, S. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35103j · Cited by 722
Metadata
- Authors
- Kumaraswamy, S., Bergstedt, T., Shi, X., Rininsland, F., Kushon, S., Xia, W., Ley, K., Achyuthan, K., McBranch, D., & Whitten, D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-05-10
- Volume
- 101
- Issue
- 20
- Pages
- 7511-7515
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1972158411
- Cited by
- 216
- References
- 2
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.