The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Microtesla MRI with a superconducting quantum interference device
Open accessAbstract
MRI scanners enable fast, noninvasive, and high-resolution imaging of organs and soft tissue. The images are reconstructed from NMR signals generated by nuclear spins that precess in a static magnetic field B0 in the presence of magnetic field gradients. Most clinical MRI scanners operate at a magnetic field B0= 1.5 T, corresponding to a proton resonance frequency of 64 MHz. Because these systems rely on large superconducting magnets, they are costly and demanding of infrastructure. On the other hand, low-field imagers have the potential to be less expensive, less confining, and more mobile. The major obstacle is the intrinsically low sensitivity of the low-field NMR experiment. Here, we show that prepolarization of the nuclear spins and detection with a superconducting quantum interference device (SQUID) yield a signal that is independent of B0, allowing acquisition of high-resolution MRIs in microtesla fields. Reduction of the strength of the measurement field eliminates inhomogeneous broadening of the NMR lines, resulting in enhanced signal-to-noise ratio and spatial resolution for a fixed strength of the magnetic field gradients used to encode the image. We present high-resolution images of phantoms and other samples and T1-weighted contrast images acquired in highly inhomogeneous magnetic fields of 132 μT; here,T1 is the spin-lattice relaxation time. These techniques could readily be adapted to existing multichannel SQUID systems used for magnetic source imaging of brain signals. Further potential applications include low-cost systems for tumor screening and imaging peripheral regions of the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device
Schlenga, K., McDermott, R., Clarke, J., de Souza, R. E., Wong-Foy, A., & Pines, A. (1999) · Applied Physics Letters · doi:10.1063/1.125432 · Cited by 67
Self-citation
Cited by
Lartigue, L., Hugounenq, P., Alloyeau, D., Clarke, S. P., Lévy, M., Bacri, J.-C., Bazzi, R., Brougham, D. F., Wilhelm, C., & Gazeau, F. (2012) · ACS Nano · doi:10.1021/nn304477s · Cited by 421
Broadband and Resonant Approaches to Axion Dark Matter Detection
Kahn, Y., Safdi, B. R., & Thaler, J. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.141801 · Cited by 364
Superparamagnetic gadonanotubes are high-performance MRI contrast agents
Sitharaman, B., Kissell, K. R., Hartman, K. B., Tran, L. A., Baikalov, A., Rusakova, I., Sun, Y., Khant, H. A., Ludtke, S. J., Chiu, W., et al. (2005) · Chemical Communications · doi:10.1039/b504435a · Cited by 349
High sensitivity magnetic imaging using an array of spins in diamond
Steinert, S., Dolde, F., Neumann, P., Aird, A., Naydenov, B., Balasubramanian, G., Jelezko, F., & Wrachtrup, J. (2010) · Review of Scientific Instruments · doi:10.1063/1.3385689 · Cited by 297
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Metadata
- Authors
- McDermott, R., Lee, S., Haken, B. T., Trabesinger, A. H., Pines, A., & Clarke, J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-05-12
- Volume
- 101
- Issue
- 21
- Pages
- 7857-7861
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2059334495
- Cited by
- 168
- References
- 2
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microtesla MRI with a superconducting quantum interference device. https://app.cochat.ai/papers/10.1073/pnas.0402382101
- The paper
- McDermott, R., Lee, S., Haken, B. T., Trabesinger, A. H., Pines, A., & Clarke, J. (2004). Microtesla MRI with a superconducting quantum interference device. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0402382101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.