Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Microtesla MRI with a superconducting quantum interference device

Open access
McDermott, Robert, Lee, SeungKyun, Haken, Bennie ten, Trabesinger, Andreas H., Pines, Alexander, Clarke, John · 2004 · Proceedings of the National Academy of Sciences

Abstract

MRI scanners enable fast, noninvasive, and high-resolution imaging of organs and soft tissue. The images are reconstructed from NMR signals generated by nuclear spins that precess in a static magnetic field B0 in the presence of magnetic field gradients. Most clinical MRI scanners operate at a magnetic field B0= 1.5 T, corresponding to a proton resonance frequency of 64 MHz. Because these systems rely on large superconducting magnets, they are costly and demanding of infrastructure. On the other hand, low-field imagers have the potential to be less expensive, less confining, and more mobile. The major obstacle is the intrinsically low sensitivity of the low-field NMR experiment. Here, we show that prepolarization of the nuclear spins and detection with a superconducting quantum interference device (SQUID) yield a signal that is independent of B0, allowing acquisition of high-resolution MRIs in microtesla fields. Reduction of the strength of the measurement field eliminates inhomogeneous broadening of the NMR lines, resulting in enhanced signal-to-noise ratio and spatial resolution for a fixed strength of the magnetic field gradients used to encode the image. We present high-resolution images of phantoms and other samples and T1-weighted contrast images acquired in highly inhomogeneous magnetic fields of 132 μT; here,T1 is the spin-lattice relaxation time. These techniques could readily be adapted to existing multichannel SQUID systems used for magnetic source imaging of brain signals. Further potential applications include low-cost systems for tumor screening and imaging peripheral regions of the body.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0402382101

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 168

Metadata

Authors
McDermott, R., Lee, S., Haken, B. T., Trabesinger, A. H., Pines, A., & Clarke, J.
Venue
Proceedings of the National Academy of Sciences
Published
2004-05-12
Volume
101
Issue
21
Pages
7857-7861
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2059334495
Cited by
168
References
2
FWCI
9.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microtesla MRI with a superconducting quantum interference device. https://app.cochat.ai/papers/10.1073/pnas.0402382101
The paper
McDermott, R., Lee, S., Haken, B. T., Trabesinger, A. H., Pines, A., & Clarke, J. (2004). Microtesla MRI with a superconducting quantum interference device. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0402382101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.